MEL_EV_HOST_REDUNDANCY_LOST - 0x9102
This event occurs when: The controller has detected that the specified host has lost connection to one of the
two controllers.
Event Name - Host Connection Redundancy Lost
Event description: Loss of host-side connection redundancy detected
Event Group - AutoLoadBalancing
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Host (0x2, 0xF)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_HOST_REDUNDANCY_LOST
MEL_EV_MULTIPATH_CONFIG_ERROR - 0x9103
This event occurs when: The behavior exhibited by the host multipath driver for the specified host does not
match expectations of the supported driver(s) for the specified host type. This usually indicates a missing,
out-of-date, or misconfigured multipath driver installed on the host or an incorrect host type specified for this
host in the array configuration.
Event Name - Multipath Configuration Error
Event description: Host multipath driver configuration error detected
Event Group - AutoLoadBalancing
Event Priority - CRITICAL_EVENT
Log Group - System (0x0)
Event Category - Error (0x1)
Event Component Type - Host (0x2, 0xF)
Event Specific Data - Optional data is not provided with this event.
RecoveryFailureType - REC_MULTIPATH_CONFIGURATION_ERROR
MEL_EV_SECURITY_AUDIT_LOG_FULL - 0x9200
This event occurs when: The Security Audit Log has reached its maximum capacity, and the Audit Log Full
Policy is set to 'Manually Clear'.
Event Name - Security Audit Log Full
Event description: Security Audit Log has reached its maximum capacity and cannot record new security
audit events until it is cleared
274
ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......