• You have completed the array side iSCSI configuration.
• You must know the IP address of each port on the controller.
These instructions assume that two NIC ports will be used for iSCSI traffic.
Step 1. Disable unused network adapter protocols.
These protocols include, but are not limited to, QoS, File and Print Sharing, and NetBIOS.
Step 2. Execute
> iscsicpl.exe
from a terminal window on the host to open the
iSCSI Initiator Properties
dialog box.
Step 3. On the
Discovery
tab, select
Discover Portal
, and then enter the IP address of one of the iSCSI
target ports.
Step 4. On the
Targets
tab, select the first target portal you discovered and then select
Connect
.
Step 5. Select
Enable multi-path
, select
Add this connection to the list of Favorite Targets
, and then
select
Advanced
.
Step 6. For
Local adapter
, select
Microsoft iSCSI Initiator
.
Step 7. For
Initiator IP
, select the IP address of a port on the same subnet or VLAN as one of the iSCSI
targets.
Step 8. For
Target IP
, select the IP address of a port on the same subnet as the
Initiator IP
selected in the
step above.
Step 9. Retain the default values for the remaining check boxes, and then select
OK
.
Step 10. Select
OK
again as you return to the
Connect to Target
dialog box.
Step 11. Repeat this procedure for each initiator port and session (logical path) to the storage array that you
want to establish.
System setup and configuration
43
Summary of Contents for DE120S
Page 96: ...90 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 282: ...276 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 284: ...278 ThinkSystem DE Series Hardware Installation and Maintenance Guide for 2U Enclosures ...
Page 291: ......
Page 292: ......