Attention:
• Read “Installation Guidelines” on page 25 to ensure that you work safely.
• Power off the server and disconnect all power cords for this task.
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
Procedure
Step 1. Remove the top cover. See “Remove the top cover” on page 30.
Step 2. Remove the riser assembly. See “Remove a riser card” on page 82.
Step 3. Remove the PCIe adapter from the riser assembly.
Figure 53. PCIe adapter removal from the LP-FH riser assembly
a. Rotate the latch on the riser bracket to the open position.
b. Grasp the PCIe adapter by its edges and carefully pull it out of the PCIe adapter slot on the
riser card.
Note:
The procedure for removing a PCIe adapter is similar for different types of riser assembly. In
this topic, the LP-FH riser assembly is used as an example.
After you finish
1. Install a PCIe adapter or PCIe adapter filler. See “Install a PCIe adapter” on page 80.
2. If you are instructed to return the old PCIe adapter, follow all packaging instructions and use any
packaging materials that are provided.
Install a PCIe adapter
Use this information to install a PCIe adapter.
About this task
Attention:
80
HR650X V2 User Guide
Summary of Contents for HR650X V2
Page 1: ...HR650X V2 User Guide Machine Types 7D4D ...
Page 8: ......
Page 14: ...6 HR650X V2 User Guide ...
Page 30: ...22 HR650X V2 User Guide ...
Page 122: ...114 HR650X V2 User Guide ...
Page 152: ...144 HR650X V2 User Guide ...
Page 176: ...168 HR650X V2 User Guide ...
Page 182: ...174 HR650X V2 User Guide ...
Page 186: ...178 HR650X V2 User Guide ...
Page 190: ...182 HR650X V2 User Guide ...
Page 191: ......
Page 192: ......