Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
–
–
•
405-904-000 : BRCM:TestInterrupt Test Failed
A failure was detected while testing interrupts.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
–
–
•
405-905-000 : BRCM:TestLoopbackMAC Test Failed
BRCM:TestLoopbackMAC Test Failed.
Appendix C. DSA diagnostic test results
1059
Summary of Contents for HX3510-G
Page 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Page 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1239: ......
Page 1240: ......