Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix:
PLAT
ID:
0520
User Response
None X8 PCI 2 Config : X8 PCI 6 Config : X8 PCI 7 Config :
•
80070128-2e01ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (ME Recovery)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701282e01ffff or 0x800701282e01ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0520
User Response
1. Restart IMM. If the error doesn't disappear, please proceed step 2.
2. Update to the latest level of iMM/uEFI code, please proceed step 3.
3.
Replace node.
•
80070201-0301ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (CPU 1 OverTemp)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702010301ffff or 0x800702010301ffff
Severity
Error
Appendix A. Integrated management module II (IMM2) error messages
391
Summary of Contents for HX3510-G
Page 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Page 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1239: ......
Page 1240: ......