800b0008-1301ffff : Redundancy [RedundancySetElementName] has been restored. (Power Unit)
This message is for the use case when an implementation has detected Redundancy was Restored.
May also be shown as 800b00081301ffff or 0x800b00081301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix:
PLAT
ID:
0561
User Response
No action; information only.
•
800b0108-1301ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Power
Unit)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b01081301ffff or 0x800b01081301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix:
PLAT
ID:
0802
User Response
1. Check the LEDs for both power supplies.
2. Follow the actions in Power-supply LEDs.
Appendix A. Integrated management module II (IMM2) error messages
419
Summary of Contents for HX3510-G
Page 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Page 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1239: ......
Page 1240: ......