Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check the operator information panel cabling for loose or broken connections at both ends or
damage to the cable.
2. Replace the information panel cable if damage is present.
3. Run the test again.
4. Replace the operator information panel assembly.
5. Run the test again.
6. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
–
–
DSA CPU stress test results
The following messages can result when you run the CPU stress test.
Test results for the DSA CPU stress test
The following messages can result when you run the DSA CPU stress test.
•
089-000-000 : CPU Stress Test Passed
CPU Stress Test Passed.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
–
–
1072
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide