IBM UPS5000 HV Uninterruptible Power Supply for IBM System x

13

Summary of Contents for IBM UPS5000

Page 1: ...ational customers implement this single model UPS5000 HV in multiple geographies The IBM UPS5000 HV uninterruptible power supply is shown in Figure 1 Figure 1 IBM UPS5000 HV uninterruptible power supply for IBM System x Did you know The UPS5000 HV packs 4500W of power into a space efficient 3U form This provides maximum power density thereby leaving more space for other computer hardware in rack a...

Page 2: ...owing items One IBM UPS5000 HV with network management card Accesory kit containing the following items Front bezel Serial cable 5m 15 ft Network Management Card console cable 2 m 6 ft Temperature sensor AP9335T on a 4 meter 13 ft cable Left and right rack mount rails Miscellaneous Hardware Kit containing the following items Miscellaneous hardware Rack mounting hardware Documentation Kit containin...

Page 3: ...s These must be ordered separately Figure 2 shows three of the four available line cords as listed in Table 1 Figure 2 Line cords l r Australian NZ Line Cord Korean Line Cord 30a Line Cord NEMA L6 30P Features IBM UPS5000 HV Uninterruptible Power Supply for IBM System x 3 ...

Page 4: ...Packs for additional runtime capacity With four external battery packs the UPS can supply up to 75 minutes of run time at full load Up to 10 external battery packs can be attached to the UPS A suite of easy to use management tools Network Management Card provides standard serial and Ethernet 10 100 MBps communications as well as connections for environmental management A temperature sensor on a 13...

Page 5: ...dity 5 to 95 Maximum altitude Operation 3 000 m 10 000 ft Storage 15 000 m 50 000 ft Warranty The IBM UPS5000 HV uninterruptible power supply has a three year limited warranty Supported rack installation The IBM UPS5000 HV uninterruptible power supply requires 3 U of rack space in one of the following rack cabinets IBM 42U Enterprise rack IBM S2 42 U Dynamic rack IBM S2 25 U rack IBM S2 42 U rack ...

Page 6: ...ry indicator 3 Battery bypass indicator 4 Overload indicator 5 Fault indicator 6 Replace battery indicator 7 Load on the uninterruptible power supply indicator 8 Power off button 9 Power on Test button 10 Battery charge level Diagnostic utility voltage indicator Rear panel Figure 4 shows the rear panel of the UPS 5000VA HV uninterruptible power supply IBM UPS5000 HV Uninterruptible Power Supply fo...

Page 7: ...andard cables are incompatible 5 Bypass switch 6 Emergency Power Off EPO terminal 7 Network management card 8 Ethernet Link LED 9 Ethernet Status LED 10 Network management card reset 11 Ethernet port 12 Environmental sensor connectors 13 USB connector reserved for future use 14 Console connector 15 Connectors for optional Online Battery Packs for extended run time remove the metal cover first 16 I...

Page 8: ...he UPS5000 HV to provide longer uptime when running on battery power Figure 6 and Figure 7 show the front and rear of the 3U Online Battery Pack Figure 6 IBM 3U Online Battery Pack front Figure 7 IBM 3U Online Battery Pack rear green yellow ground wire not shown Figure 8 shows the UPS connected to two 3U Online Battery Packs The units are connected together using the battery connectors shown in Fi...

Page 9: ...ate run times for the uninterruptible power supply when operating on battery power The run times vary depending on the load attached to the UPS The table also lists the run times when one two three or four 3U Online Battery Packs OBP are attached Table 2 Run times when running on battery IBM UPS5000 HV Uninterruptible Power Supply for IBM System x 9 ...

Page 10: ...43 6 14 1200 W 0 32 1 30 2 41 3 55 5 11 1400 W 0 26 1 16 2 17 3 20 4 25 1600 W 0 22 1 06 1 59 2 54 3 50 1800 W 0 19 0 58 1 45 2 33 3 23 2000 W 0 17 0 52 1 33 2 17 3 01 2500 W 0 12 0 40 1 13 1 47 2 22 3000 W 0 09 0 32 1 00 1 28 1 57 3400 W 0 07 0 25 0 50 1 12 1 40 4000 W 0 06 0 23 0 43 1 00 1 25 4500 W 0 05 0 20 0 38 0 54 1 15 Table 3 lists the number of hours needed to recharge the IBM UPS5000 HV ...

Page 11: ...tery Pack Operation and Setup Guide ftp ftp software ibm com systems support system_x_pdf 25r5637a pdf IBM System x Configuration and Options Guide http www ibm com support docview wss uid psg1SCOD 3ZVQ5W Related product families Product families related to this document are the following Uninterruptible Power Supplies IBM UPS5000 HV Uninterruptible Power Supply for IBM System x 11 ...

Page 12: ...ded for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties All informatio...

Page 13: ...list of Lenovo trademarks is available on the Web at http www3 lenovo com us en legal copytrade The following terms are trademarks of Lenovo in the United States other countries or both BladeCenter Lenovo System x Other company product or service names may be trademarks or service marks of others IBM UPS5000 HV Uninterruptible Power Supply for IBM System x 13 ...