0
CIM Information
Prefix:
PLAT
ID:
0498
User Response
1. Make sure that the water loop is operating, the relevant water tubes are in place and correctly
installed, and that the server cover is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Make sure that the heat sink for microprocessor n.
4. (Trained technician only) Replace system board.
•
80010b01-3706ffff : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted. (GPU Outlet Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
May also be shown as 80010b013706ffff or 0x80010b013706ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix:
PLAT
ID:
0498
User Response
1. Make sure that the water loop is operating, the relevant water tubes are in place and correctly
installed, and that the server cover is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Make sure that the heat sink for microprocessor n.
4. (Trained technician only) Replace system board.
•
80010b01-3707ffff : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted. (HDD Outlet Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
May also be shown as 80010b013707ffff or 0x80010b013707ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Appendix A. Integrated Management Module 2.1 (IMM2.1) error messages
271
Summary of Contents for NeXtScale n1200
Page 115: ...Chapter 6 Removing and replacing server components 101 ...
Page 117: ...Chapter 6 Removing and replacing server components 103 ...
Page 119: ...Chapter 6 Removing and replacing server components 105 ...
Page 135: ...Chapter 6 Removing and replacing server components 121 ...
Page 137: ...Chapter 6 Removing and replacing server components 123 ...
Page 139: ...Chapter 6 Removing and replacing server components 125 ...
Page 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Page 877: ......
Page 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...