AC power-supply LEDs
AC
DC
Error (!)
Description
Action
Notes
On
Off
Off
Power-supply not
fully seated, faulty
system board, or
the power supply
has failed.
1. Reseat the power supply.
2. Follow actions in “Power
3. Follow actions in “Solving
power problems” on page 71
until the problem is solved.
Typically indicates a
power-supply is not
fully seated.
On
Off
On
The power supply
has failed.
Replace the power supply.
On
On
On
The power supply
has failed.
Replace the power supply.
System pulse LEDs
Use this information to view the system pulse LEDs.
The following LEDs are on the system board and monitor the system power-on and power-off sequencing
and boot progress (see “System-board LEDs and controls” on page 19 for the location of these LEDs).
Table 2. System pulse LEDs
LED
Description
Action
RTMM heartbeat
Power-on and power-off
sequencing.
1. If the LED blinks at 1Hz, it is functioning
properly and no action is necessary.
2. If the LED is not blinking, (trained technician
only) replace the system board.
IMM2 heartbeat
IMM2 heartbeat boot process.
The following steps describe the different stages
of the IMM2 heartbeat sequencing process.
1. When this LED is blinking fast
(approximately 4Hz), this indicates,
that the IMM2 code is in the loading
process.
2. When this LED goes off momentarily, this
indicates that the IMM2 code has loaded
completely.
3. When this LED goes off momentarily and
then starts blinking slowing (approximately
1Hz), this indicates that IMM2 is fully
operational. You can now press the
power-control button to power-on the
server.
4. If this LED does not blink within 30 seconds
of connecting a power source to the server,
(trained technician only) replace the system
board.
Event logs
Error codes and messages displayed in POST event log, system-event log, integrated management module
(IMM2) event log, and DSA event log.
53
Summary of Contents for NeXtScale nx360 M4
Page 1: ...IBM NeXtScale nx360 M4 Installation and Service Guide Machine Type 5455 ...
Page 6: ...iv IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 34: ...20 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 58: ...44 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 94: ...80 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 192: ...178 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 538: ...524 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 562: ...548 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 722: ......
Page 730: ......
Page 737: ......
Page 738: ...Part Number 00KC216 Printed in China 1P P N 00KC216 1P00KC216 ...