Step 11. Move the UEFI boot backup jumper (JP2) from pins 2 and 3 back to the primary position (pins 1
and 2).
Step 12. Reinstall the cover (see “Installing the compute node cover” on page 107).
Step 13. Reconnect the power cord and any cables that you removed.
Step 14. Restart the server. The system begins the power-on self-test (POST). If this does not recover the
primary bank, continue with the following steps.
Step 15. Remove the cover (see “Removing the compute node cover” on page 105).
Step 16. Reset the CMOS by removing the system battery (see “Removing the system battery” on page 126).
Step 17. Leave the system battery out of the server for approximately 5 to 15 minutes.
Step 18. Reinstall the system battery (see “Replacing the system battery” on page 127).
Step 19. Reinstall the cover (see “Installing the compute node cover” on page 107).
Step 20. Reconnect the power cord and any cables that you removed.
Step 21. Restart the server. The system begins the power-on self-test (POST).
Step 22. If these recovery efforts fail, contact your IBM service representative for support.
In-band automated boot recovery method
Use this information to use the in-band automated boot recovery method.
Note:
Use this method if the system-error LED on the operator information panel is lit and there is a log
entry or
Booting Backup Image
is displayed on the firmware splash screen; otherwise, use the in-band
manual recovery method.
Step 1.
Boot the server to an operating system that is supported by the firmware update package that
you downloaded.
Step 2.
Perform the firmware update by following the instructions that are in the firmware update package
readme file.
Step 3.
Restart the server.
Step 4.
At the firmware splash screen, press F3 when prompted to restore to the primary bank. The
server boots from the primary bank.
Out-of-band method
Use this information to use the out-of-band method.
See the IMM2 documentation (
Integrated Management Module II User's Guide
) at
http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=migr-5086346.
Automated boot recovery (ABR)
While the server is starting, if the integrated management module II detects problems with the server
firmware in the primary bank, the server automatically switches to the backup firmware bank and gives you
the opportunity to recover the firmware in the primary bank.
For instructions for recovering the UEFI firmware, see “Recovering the server firmware (UEFI update failure)”
on page 75. After you have recovered the firmware in the primary bank, complete the following steps:
Step 1.
Restart the server.
Step 2.
When the prompt
Press F3 to restore to primary
is displayed, press F3 to start the server from
the primary bank.
78
IBM NeXtScale nx360 M4 Installation and Service Guide
Summary of Contents for NeXtScale nx360 M4
Page 1: ...IBM NeXtScale nx360 M4 Installation and Service Guide Machine Type 5455 ...
Page 6: ...iv IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 34: ...20 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 58: ...44 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 94: ...80 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 192: ...178 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 538: ...524 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 562: ...548 IBM NeXtScale nx360 M4 Installation and Service Guide ...
Page 722: ......
Page 730: ......
Page 737: ......
Page 738: ...Part Number 00KC216 Printed in China 1P P N 00KC216 1P00KC216 ...