Repair Manual of Lenovo P70-A Mobile Phone
23
Check whether RF
connector J1001
is in cold
solder joint?
Re-weld
J1001
Whether R137 is in cold
solder joint?
Re-weld
Whether U1002
Rx is in cold
solder joint?
Whether U1001Rx is in
cold solder joint?
Check calibration report to see
whether the two frequency
bands fail?
Check whether RF cable
and fixtures are well
connected?
Reconnect and
calibrate
GSM frequency
band fails?
Whether
X801
is
in
cold solder joint
Re-weld
Re-weld or
replace
Whether Rx is in cold
solder joint?
Re-weld
Re-weld
Whether C809 are in cold
solder joint?
Whether U801 Rx is in cold
solder joint?
Check the baseband chip
U401
Re-weld
Re-weld or
replace
4.11.2
AGC
Fault: AGC calibration Fail.
Reason: RF test cable is not connected well during calibration; the devices in receiving
cable are in cold solder joint (such as RF connectors, antenna switch, saw the filter and
the surrounding capacitance).
Shooting
:
Notes: Remeber to recalibrate after replacing compoments.
Rx path lo
calibration fails
N
N
N
Y
Y
Y
N
Y
N
Y
N
Y
N
Y
N
Y
N
Y
Y
N
Y
Summary of Contents for P70-A
Page 1: ...Service Manual of Lenovo P70 A Mobile Phone Lenovo ...
Page 5: ...Version No Prepared by Modified by Prepared Modified on Reason for change Main changes ...
Page 6: ...1 Appearance ...
Page 8: ...Repair Manual of Lenovo P70 A Mobile Phone 7 3 Baseband Block diagram of hardware system ...
Page 37: ...Repair Manual of Lenovo P70 A Mobile Phone 36 Figure 9 ...
Page 40: ...Repair Manual of Lenovo P70 A Mobile Phone 39 Figure 14 ...