Repair Manual of Lenovo P70-A Mobile Phone
24
Weld PA
Whether RF connector
are in cold solder joint?
Re-weld
Whether related
components is in cold
solder joint?
Re-weld
Whether PA is in
cold solder joint?
PA input circuit are
welded with
disconnection?
Check calibration report to
see whether each frequency
bands fail?
Check whether RF
cable and fixtures are
well connected?
Reconnect
and calibrate
2G/3G
frequency fails?
LTE frequency fail
Replace
components
PA input circuit are
welded with
disconnection
?
Whether PA is in
cold solder joint?
Replace PA
4.11.3
APC
Fault 1
Fault: APC calibration Fail.
Cause: RF test cable is not connected well during calibration; PA is oppositely pasted; PA
and peripheral circuit are in cold solder joint; The patch of RF input circuit of PA is deviated
with short-circuit shield box.
Shooting:
PCL calibration Fail
Y
N
Y
N
Y
Y
N
N
Y
Y
Re-weld
Y
N
Y
N
Y
Summary of Contents for P70-A