Repair Manual of Lenovo P70-A Mobile Phone
25
Check RF cable and fixtures to
ensure well connection
Reconnect and calibrate
Fault 2:
Fault: The output power of the mobile phone is too high.
Cause: The cable isn't well connected in calibration.
Shooting:
Fault 3:
Fault: After repeated calibration, the power is still low.
Cause: Some element patches of PA and surrounding VAPC input are displaced or PA is
damaged.
Shooting:
After repeated calibration, the
power is still low.
Related PA may be
partially damaged;
recalibrate.
Replace
Vramp
circuit
N
Calibration power is too high