629
FCoE VLAN Configuration
Use
the
following
commands
to
configure
the
FCoE
VLAN.
Table 356.
FCoE
VLAN
Options
Command Syntax and Usage
fcoe
fcf
priority
<0
‐
255>
Configures
the
FCF
priority.
When
an
FC
initiator
sends
login
requests
to
multiple
FCFs,
it
selects
the
one
with
the
highest
priority
value.
The
default
value
is
128
.
Command
mode:
VLAN
no
fcoe
fcf
priority
Resets
the
FCF
priority
to
the
default
128
value.
Command
mode:
VLAN
fcoe
fcmap
<0xefc00
‐
0xefcff>
Configures
the
global
FC
‐
map
that
identifies
the
FC
fabric
used
by
the
switch.
The
switch
will
discard
MAC
addresses
that
are
not
part
of
the
current
fabric,
which
avoids
cross
‐
fabric
talk.
The
FC
‐
map
is
a
24
‐
bit
hexadecimal
value.
The
default
value
is
0x0efc00
.
Command
mode:
VLAN
no
fcoe
fcmap
[
<0xefc00
‐
0xefcff>
]
Resets
all
the
FC
‐
maps
or
a
specific
FC
‐
map
to
the
default
0x0efc00
value.
Command
mode:
VLAN
fcoe
fka
adv
period
<4000
‐
90000>
Configures
the
FIP
Keep
Alive
advertising
period,
in
milliseconds.
The
default
value
is
8000
.
Command
mode:
VLAN
no
fcoe
fka
adv
period
Resets
the
FIP
Keep
Alive
advertising
period
to
its
default
value
of
8000
miliseconds.
Command
mode:
VLAN
Summary of Contents for RackSwitch G8332
Page 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Page 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Page 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Page 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Page 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Page 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Page 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...