Lenovo Storage S3200/S2200 Setup Guide
55
When a temperature fault is reported, it must be remedied as quickly as possible to avoid system damage.
This can be done by warming or cooling the installation location.
When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is
logged to the event log.
Power supply module voltage sensors
Power supply voltage sensors ensure that an enclosure’s power supply voltage is within normal ranges.
There are three voltage sensors per power supply.
Table 20
Controller module temperature sensor descriptions
Description
Normal operating
range
Warning operating
range
Critical operating
range
Shutdown values
CPU temperature
3
C–88
C
0
C–3
C,
88
C–90
C
>
90
C
0
C
100
C
FPGA temperature
3
C–97
C
0
C–3
C,
97
C–100
C
None
0
C
105
C
Onboard temperature 1
0
C–70
C
None
None
None
Onboard temperature 2
0
C–70
C
None
None
None
Onboard temperature 3
(Capacitor temperature)
0
C–70
C
None
None
None
CM temperature
5
C–50
C
5
C,
50
C
0
C,
55
C
None
Table 21
Power supply temperature sensor descriptions
Description
Normal operating range
Power supply 1 temperature
–10
C–80
C
Power supply 2 temperature
–10
C–80
C
Table 22
Voltage sensor descriptions
Sensor
Event/Fault LED condition
Power supply 1 voltage, 12V
< 11.00V
> 13.00V
Power supply 1 voltage, 5V
< 4.00V
> 6.00V
Power supply 1 voltage, 3.3V
< 3.00V
> 3.80V