18
SI4091 10Gb System Interconnect Module Installation Guide
Installing the SI4091
Note:
The following illustration shows how to install the switch in a Lenovo Flex
System chassis. The appearance of your Lenovo Flex System chassis might be
different; see the documentation for your Lenovo Flex System chassis for
additional information.
Use the following instructions to install the switch in the Lenovo Flex System
chassis. You can install the switch while the Lenovo Flex System chassis is powered
on. For redundancy support, you must install I/O modules of the same type in I/O
bays 1 and 2, and I/O modules of the same type in bays 3 and 4 of the chassis.
To install the switch, complete the following steps.
1.
Read the safety information that begins on
2.
Select I/O bay in which to install the switch.
Note:
For details about I/O bay requirements and bay locations, see the
documentation for the Lenovo Flex System chassis.
3.
Remove the filler module from the selected bay. Store the filler module for future
use.
4.
If you have not already done so, touch the static-protective package that contains
the switch to an
unpainted
metal surface of the Lenovo Flex System chassis or an
unpainted
metal surface on any other grounded rack-component for at least 2
seconds.
5.
Remove the switch from its static-protective package.
6.
Make sure that the release levers on the switch are in the open position
(perpendicular to the switch).
7.