806f0021-3004ffff : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (PCI 4)
This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00213004ffff or 0x806f00213004ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0330
User Response
1.
Check the PCI LED.
2. Reseat the affected adapters and riser card.
3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
4.
Remove both adapters.
5.
Replace the riser card.
6. (Trained service technicians only) Replace the system board.
•
806f0021-3005ffff : Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName]. (PCI 5)
This message is for the use case when an implementation has detected a Fault in a slot.
May also be shown as 806f00213005ffff or 0x806f00213005ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
472
System x3500 M4 Installation and Service Guide
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......