1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
•
I.580A6 [I.580A6] Memory spare copy has completed successfully.
Explanation:
Spare Copy Complete
Severity
Info
User Response
Complete the following steps:
1. Check system log for related DIMM failures and replace those DIMMs.
•
S.1100B [S.1100B] CATERR(IERR) has asserted on processor %.
Explanation:
Processor CATERR(IERR) has asserted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
2. (Trained Service technician only) Replace the Processor.
•
S.1100C [S.1100C] An uncorrectable error has been detected on processor %.
Explanation:
Uncorrectable processor error detected
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reboot system. If problem persists escalate to the next level of supprt.
•
S.2011001 [S.2011001] An Uncorrected PCIe Error has Occurred at Bus % Device % Function %.
The Vendor ID for the device is % and the Device ID is %.
Explanation:
PCI SERR Detected
Severity
Error
User Response
Complete the following steps:
1. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
Appendix B. UEFI (POST) error codes
973
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......