To install the air baffle (two microprocessors installed), complete the following steps.
Step 1.
Carefully turn the server on its side so that it is lying flat, with the cover facing up.
Attention:
Do not allow the server to fall over.
Step 2.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 184).
Step 3.
Align the positioning pins on the ends of the air baffle with the locating holes in the server chassis
and fan cage assembly.
Step 4.
Slide the air baffle down into the server until the positioning pins fit into the locating holes; then,
press down on the air baffle until the pinch tab clicks into place.
00
00
00
000
000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
0000
0000
0000
0000
0000
000000000
000000000
000000000
000000000
000000000
000000000
000000000
000000000
000000000
000000000
Air baffle
Figure 105. Air baffle installation
Step 5.
Install and lock the left-side cover (see “Installing the left-side cover” on page 185).
If you have replaced a server component or installed an optional device in the server, you need to reconnect
the power cords and all external cables, and turn on the server and peripheral devices.
Removing a RAID adapter battery or flash power module holder
Use this information to remove a RAID adapter battery or flash power module holder.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 35.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
Removing and replacing components
191
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......