Step 4.
Reconnect the external cables and power cords; then, turn on the attached devices and turn on
the server.
Note:
You must wait approximately 3 minutes after you connect the server power cord to an
electrical outlet before the power-control button becomes active.
Step 5.
Start the Setup utility and reset the configuration:
a.
Set the system date and time.
b.
Set the power-on password.
c.
Reconfigure the server.
See “Starting the Setup utility” on page 107 for details.
Removing the USB cable and light path diagnostics assembly
Use this information to remove the USB cable and light path diagnostics assembly.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 35.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To remove the USB cable and light path diagnostics assembly from the server, complete the following steps.
Step 1.
Carefully lay the server down on its side.
Step 2.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 184).
Step 3.
Remove the air baffle (see “Removing the air baffle” on page 189).
Step 4.
Remove the fan cage assembly (see “Removing the fan cage assembly” on page 272).
Step 5.
Disconnect the light path diagnostics cable from the system board (see “System-board internal
connectors” on page 27 and “Internal cable routing and connectors” on page 312).
Step 6.
Stand the server back up in its vertical position.
Step 7.
Open the bezel by pressing the button on the left edge of the bezel, and rotate the left side of the
bezel away from the server.
Step 8.
Press down on the release latch on the bottom of the USB cable and light path diagnostics
assembly bracket; then, rotate the top of the mounting bracket away from the server.
Removing and replacing components
237
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......