Hazardous voltage, current, and energy levels are present inside any component that has this label
attached. There are no serviceable parts inside these components. If you suspect a problem with
one of these parts, contact a service technician.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 35.
Attention:
Static electricity that is released to internal server components when the server is powered-on
might cause the server to halt, which might result in the loss of data. To avoid this potential problem,
always use an electrostatic-discharge wrist strap or other grounding system when you work inside the
server with the power on.
To remove a hot-swap power supply, complete the following steps.
Notes:
1. If only one hot-swap power supply is installed in the server, you must turn off the server before removing
the power supply.
2. You must install the fan cage assembly before removing or installing the power supply.
Step 1.
Disconnect the power cord from the connector on the back of the power supply that you are
removing.
Step 2.
Press the release latch on the hot-swap power supply and pull it out from the server.
0
0
0
000000
000000
000000
000000
000000
000000
000000
000000
000000
000000
000000
000000
000000
000
000
000
000
000
000
000
00000
00000
00000
Hot-swap
power supply
Release
latch
Hot-swap
power-supply
filler panel
Power supply 1
Power supply 2
Figure 172. Hot-swap power supply removal
If you are instructed to return the server component or optional device, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Installing a hot-swap power supply
Use this information to install a hot-swap power supply.
The following notes describe the type of ac power supply that the server supports and other information that
you must consider when you install a power supply:
Removing and replacing components
255
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......