Power supplies
Figure 175. Attach redundant power information
Removing the operator information panel assembly
Use this information to remove the operator information panel assembly.
Read the safety information in “Safety” on page v and “Installation guidelines” on page 35.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To remove the operator information panel assembly, complete the following steps.
Step 1.
Unlock and remove the left-side cover (see “Removing the left-side cover” on page 184).
Step 2.
Remove the air baffle (see “Removing the air baffle” on page 189).
Step 3.
Remove the fan cage assembly (see “Removing the fan cage assembly” on page 272).
Step 4.
Disconnect the drive cables from the back of the drive bay 1.
Step 5.
Remove the DVD drive (see “Removing a DVD drive” on page 205) or the tape drive (see “Removing
an optional tape drive” on page 208) which is installed in drive bay 1.
Step 6.
Disconnect the operator information panel assembly cable from the system board (see
“System-board internal connectors” on page 27).
Step 7.
Locate the operator information panel assembly release latch just above the DVD drive.
Removing and replacing components
259
Summary of Contents for System x3500 M4
Page 1: ...System x3500 M4 Installation and Service Guide Machine Type 7383 ...
Page 6: ...iv System x3500 M4 Installation and Service Guide ...
Page 14: ...xii System x3500 M4 Installation and Service Guide ...
Page 140: ...126 System x3500 M4 Installation and Service Guide ...
Page 180: ...166 System x3500 M4 Installation and Service Guide ...
Page 194: ...180 System x3500 M4 Installation and Service Guide ...
Page 978: ...964 System x3500 M4 Installation and Service Guide ...
Page 1002: ...988 System x3500 M4 Installation and Service Guide ...
Page 1160: ...1146 System x3500 M4 Installation and Service Guide ...
Page 1164: ...1150 System x3500 M4 Installation and Service Guide ...
Page 1172: ...Taiwan BSMI RoHS declaration 1158 System x3500 M4 Installation and Service Guide ...
Page 1181: ......
Page 1182: ......