Microprocessor:
v
Intel
Xeon
™
dual-core
or
quad-core
with
12
MB
Level-2
cache
Important:
Do
not
use
dual-core
and
quad-core
processors
in
the
same
server.
v
Support
for
up
to
two
microprocessors
v
Support
for
Intel
Extended
Memory
64
Technology
(EM64T)
Note:
Use
the
Configuration/Setup
Utility
program
to
determine
the
type
and
speed
of
the
microprocessors.
Memory:
v
Minimum:
1
GB
depending
on
server
model,
expandable
to
48
GB
v
Type:
667
MHz,
PC2-5300,
ECC
Fully
Buffered
DIMMs
(FBD)
with
double
data
rate
(DDR)
II,
SDRAM
v
Connectors:
Twelve
240-pin
dual
inline
memory
module
(DIMM)
connectors
Drives:
v
IDE:
–
DVD
(standard)
–
CD,
CD-RW,
DVD/CD-RW
(optional)
–
Maximum
of
two
devices
can
be
installed
v
Diskette
(optional):
External
USB
1.44
MB
v
Supported
hard
disk
drives:
–
Serial
Attached
SCSI
(SAS)
–
Serial
Advanced
Technology
Attachment
(SATA)
Expansion
bays:
v
Eight
hot-swap
SAS,
3.5-inch
bays
or
12
hot-swap
SAS,
2.5-inch
bays
v
Three
half-high
5.25-inch
bays
(DVD
drive
installed)
Note:
Full-high
devices
such
as
an
optional
tape
drive
will
occupy
two
half-high
5.25-inch
bays.
PCI
and
PCI-X
expansion
slots:
v
Six
PCI
expansion
slots
–
Three
PCI
Express
x8
(two
x8
links
and
one
x4
link)
slots
–
One
PCI
33
MHz/32-bit
slot
–
Two
PCI-X
2.0
133
MHz/64-bit
slots
Upgradeable
microcode:
System
BIOS,
service
microprocessor,
BMC,
and
SAS
microcode
Power
supply:
Note:
To
upgrade
to
two
835-watt
hot-swap
power
supplies,
install
the
redundant
power
and
cooling
option
kit.
Kit
includes
one
835-watt
power-supply
and
three
hot-swap
fans.
v
Standard:
One
835-watt
110
V
or
240
V
ac
input
dual-rated
power
supply
v
Upgradeable
to
two
835-watt
hot-swap
power
supplies
Hot-swap
fans:
v
Three
(standard)
v
Upgradeable
to
six
fans
(for
redundant
cooling)
Note:
To
upgrade
to
redundant
cooling,
install
the
redundant
power
and
cooling
option
kit.
Kit
includes
one
835-watt
hot-swap
power-supply
and
three
hot-swap
fans.
Size:
v
Tower
–
Height:
440
mm
(17.3
in.)
–
Depth:
747
mm
(29.4
in.)
–
Width:
218
mm
(8.6
in.)
–
Weight:
approximately
38
kg
(84
lb)
when
fully
configured
or
20
kg
(42
lb)
minimum
v
Rack
–
5
U
–
Height:
218
mm
(8.6
in.)
–
Depth:
696
mm
(27.4
in.)
–
Width:
424
mm
(16.7
in.)
–
Weight:
approximately
34
kg
(75
lb)
when
fully
configured
or
20
kg
(42
lb)
minimum
Racks
are
marked
in
vertical
increments
of
4.45
cm
(1.75
inches).
Each
increment
is
referred
to
as
a
unit,
or
“U.”
A
1-U-high
device
is
4.45
cm
(1.75
inches)
tall.
Integrated
functions:
v
Baseboard
management
controller
(Intelligent
Platform
Management
Interface
(IPMI)
2.0
compliant)
v
Easy
LED
diagnostics
v
ServeRAID-8k
(512
MB
with
battery
backup)
and
ServeRAID-8s
SAS
Controllers
support
RAID
levels
0,
1,
1E,
,10,
5,
6,
50,
and
60
Note:
The
server
will
not
start
without
a
RAID
controller
installed.
–
Eight
3.5–inch
hard
disk
drive
models:
ServeRAID-8k-l
or
ServeRAID-8k
–
Twelve
2.5-inch
hard
disk
drive
models:
ServeRAID-8k
and
ServeRAID-8s
v
Four
Universal
Serial
Bus
(USB)
ports
(2.0)
–
Two
on
rear
of
server
–
Two
on
front
of
server
v
Broadcom
5721
and
5721KFB3
10/100/1000
Gigabit
Ethernet
controllers
v
ATI
PCI
ES1000
video
–
16
MB
video
memory
–
VGA
and
SVGA
compatible
v
ATA-100
single-channel
IDE
controller
(bus
mastering)
v
Vitesse
VSC7250
SAS/SATA
RAID
controller
v
Mouse
connector
v
Keyboard
connector
v
Serial
connector
Acoustical
noise
emissions:
v
Sound
power,
idle:
5.5
bel
declared
v
Sound
power,
operating:
6.0
bel
declared
Environment:
v
Air
temperature:
–
Server
on:
10°
to
35°C
(50.0°
to
95.0°F);
altitude:
0
to
2134
m
(7000
ft)
–
Server
off:
-40°
to
60°C
(-40.0°
to
140.4°F);
maximum
altitude:
2134
m
(7000
ft)
v
Humidity:
–
Server
on:
8%
to
80%
–
Server
off:
8%
to
80%
Heat
output:
Approximate
heat
output
in
British
thermal
units
(Btu)
per
hour:
v
Minimum
configuration:
2013
Btu
per
hour
(590
watts)
v
Maximum
configuration:
2951
Btu
per
hour
(865
watts)
Electrical
input:
v
Sine-wave
input
(50-60
Hz)
required
v
Input
voltage
low
range:
–
Minimum:
100
V
ac
–
Maximum:
127
V
ac
v
Input
voltage
high
range:
–
Minimum:
200
V
ac
–
Maximum:
240
V
ac
v
Approximate
input
kilovolt-amperes
(kVA):
–
Minimum:
0.60
kVA
–
Maximum:
0.88
kVA
Notes:
1.
Power
consumption
and
heat
output
vary
depending
on
the
number
and
type
of
optional
features
that
are
installed
and
the
power-management
optional
features
that
are
in
use.
2.
These
levels
were
measured
in
controlled
acoustical
environments
according
to
the
procedures
that
are
specified
by
the
American
National
Standards
Institute
(ANSI)
S12.10
and
ISO
7779
and
are
reported
in
accordance
with
ISO
9296.
Actual
sound-pressure
levels
in
a
given
location
might
exceed
the
average
stated
values
because
of
room
reflections
and
other
nearby
noise
sources.
The
declared
sound-power
levels
indicate
an
upper
limit,
below
which
a
large
number
of
computers
will
operate.
4
ThinkServer
TD100
and
TD100x
Types
4203,
4204,
4205,
4206,
6398,
6399,
6419,
and
6429:
User
Guide
Summary of Contents for TD100 - THINKSERVER 2.0G 2GB DVD 670W 6X7 TFF
Page 1: ...ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 2: ......
Page 3: ...ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 92: ...78 ThinkServer TD100 and TD100x Types 4203 4204 4205 4206 6398 6399 6419 and 6429 User Guide ...
Page 97: ......
Page 98: ...Part Number 46U0858 Printed in USA 1P P N 46U0858 ...