Procedure performed by
: customer or field service
Complete the following steps to install the 10GbE cage (SFP+) model EIOM.
Step 1. Grasp the EIOM and align the four EIOM tabs with the slots in the shuttle. Then, lower the EIOM
into the slots, and then pull the EIOM slightly towards the rear side of the shuttle.
Step 2. Connect required cables to the EIOM.
Step 3. Turn the thumbscrews clockwise.
Figure 52. EIOM installation
The installation of the EIOM is now complete.
After you install the EIOM, complete the following steps:
1. Reinstall the shuttle (see
http://thinksystem.lenovofiles.com/help/topic/7X21/install_the_shuttle.html
).
2. If the cable management arm is removed, install it (see
http://thinksystem.lenovofiles.com/help/topic/7X21/
install_the_cable_management_arm.html
3. Reconnect the power cords and any cables that you removed.
4. Push all compute nodes back into the enclosure (see
http://thinksystem.lenovofiles.com/help/topic/7X21/
install_a_compute_node_in_the_chassis.html
5. Turn on all compute nodes.
6. Exit maintenance mode.
7. Check the following to verify whether the EOIM has been successfully replaced:
• The amber warning light on the node front panel is off.
• All the network ports on the EIOM are fully functional.
8. If you are instructed to return the component or optional device, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
.
Part replacement and maintenance procedures
109
Summary of Contents for ThinkAgile CP
Page 4: ...ii Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 6: ...iv Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 8: ...vi Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 30: ...22 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 33: ...Chapter 4 Managing Support Mode 25 ...
Page 80: ...72 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 158: ...150 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 160: ...152 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 161: ......
Page 162: ......