To install the ThinkSystem NE0152T RackSwitch in a standard equipment rack, complete the following
steps:
Step 1. Locate, record, and retain the product switch information in order to configure and register your
product.
Step 2. Attach a mounting bracket (item 1 in the illustration) to each side of the switch with M4 screws (item
2). Torque the screws to approximately 2.0 newton‐meters (Nm) ± 0.1 Nm (17.7 inch‐pounds).
Figure 69. Attaching mounting brackets to switch
Step 3. From the front, slide the switch into the rack at the desired height.
Step 4. Secure the switch unit to the rack posts with M6 screws (item 3 in illustration), washers (item 6), and
either clip nuts (item 4) or cage nuts (item 5). Torque the screws to approximately 5.7 Nm ± 0.1 Nm
(50 inch‐pounds).
Figure 70. Securing switch to rack posts
.
Part replacement and maintenance procedures
147
Summary of Contents for ThinkAgile CP
Page 4: ...ii Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 6: ...iv Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 8: ...vi Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 30: ...22 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 33: ...Chapter 4 Managing Support Mode 25 ...
Page 80: ...72 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 158: ...150 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 160: ...152 Lenovo ThinkAgile CP Hardware Part Replacement and Component Maintenance Procedures ...
Page 161: ......
Page 162: ......