![background image](http://html.mh-extra.com/html/lenovo/thinkagile-hx1521-r/thinkagile-hx1521-r_user-manual_202680017.webp)
Each hot-swap drive has two LEDs.
Drive LED
Status
Description
7
Drive activity LED
Solid green
The drive is powered but not active.
Blinking green
The drive is active.
8
Drive status LED
Solid yellow
The drive has an error.
Blinking yellow (blinking slowly, about one
flash per second)
The drive is being rebuilt.
Blinking yellow (blinking rapidly, about four
flashes per second)
The RAID adapter is locating the drive.
9
Drive bay filler
The drive bay filler is used to cover vacant drive bays.
Front I/O assembly
The front I/O assembly of the server provides controls, connectors, and LEDs. The front I/O assembly varies
by model.
The following illustrations show the controls, connectors, and LEDs on the front I/O assembly of the server.
To locate the front I/O assembly, see “Front view” on page 11.
Figure 6. Front I/O assembly
Table 3. Components on the front I/O assembly
Callout
Callout
1
XClarity Controller USB connector
2
USB 3.0 connector
3
Power button with power status LED
4
Network activity LED
5
System ID button with system ID LED
6
System error LED
.
13