background image

Capacity tier: SATA 6Gb SSDs - PM883 Entry
ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD

4XB7A10195 B34H

2 / 7

ThinkSystem 2.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD

4XB7A10196 B34J

2 / 7

ThinkSystem 2.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD

4XB7A10197 B34K

2 / 7

ThinkSystem 2.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD

4XB7A10198 B34L

2 / 7

ThinkSystem 2.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD

4XB7A10199 B34M

2 / 7

ThinkSystem 2.5" PM883 7.68TB Entry SATA 6Gb Hot Swap SSD

4XB7A10200 B4D2

2 / 7

Capacity tier: SATA 6Gb SSDs - S4500 Entry
ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD

7SD7A05740 B0Z0

2 / 7

ThinkSystem 2.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD

7SD7A05739 B0Z1

2 / 7

ThinkSystem 2.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD

7SD7A05738 B0Z2

2 / 7

Capacity tier: SATA 6Gb SSDs - S4510 Entry
ThinkSystem 2.5" Intel S4510 480GB Entry SATA 6Gb Hot Swap SSD

4XB7A10248 B499

2 / 7

ThinkSystem 2.5" Intel S4510 960GB Entry SATA 6Gb Hot Swap SSD

4XB7A10249 B49A

2 / 7

ThinkSystem 2.5" Intel S4510 1.92TB Entry SATA 6Gb Hot Swap SSD

4XB7A13622 B49B

2 / 7

ThinkSystem 2.5" Intel S4510 3.84TB Entry SATA 6Gb Hot Swap SSD

4XB7A13623 B49C

2 / 7

Description

Part number

Feature
code

Quantity per
drive group
(min / max)

Configuration notes:

The VX3320 appliance supports up to 3 drive groups. Each drive group contains 1 cache drive and up to
7 capacity drives depending on the quantity of the drive groups:

1 drive group: From 2 to 7 capacity drives.
2 drive groups: From 2 to 4 capacity drives in each group.
3 drive groups: 2 capacity drives in each group.

The quantity of the capacity drives in each drive group must be the same.
All cache drives in the appliance must be of the same model and capacity. All capacity drives in the
appliance must be of the same model and capacity.
The withdrawn VX3320 (7Y13) appliance does not support NVMe PCIe SSD cache drives.

I/O expansion

The VX3320 appliance supports one LOM card slot and up to four PCIe slots: one slot on the system planar that
is dedicated to an internal storage controller and up to three PCIe slots with different riser cards installed into two
riser sockets on the system planar (one riser socket supports installation of one riser card).

The slot form factors are as follows:

LOM card slot
Slot 1: PCIe 3.0 x8, ML2 x8, or ML2 x16; low profile
Slot 2: PCIe 3.0 x16 or x8; low profile or full-height, half-length
Slot 3: PCIe 3.0 x16; low profile
Slot 4: PCIe 3.0 x8 (dedicated to an internal storage controller)

Configuration note:

 Slot 3 requires the second processor to be installed.

Lenovo ThinkAgile VX3320 Appliance (Xeon SP Gen 1) (withdrawn product)

15

Summary of Contents for ThinkAgile VX3320

Page 1: ...ffice and branch office workloads The ThinkAgile VX3320 for compute heavy workloads is a 1U rack mount appliance that supports up to two processors up to 3 TB of 2666 MHz TruDDR4 memory 6x 2 5 inch SAS SATA and 4x 2 5 inch AnyBay drive bays with an extensive choice of NVMe PCIe SSDs SAS SATA SSDs and SAS HDDs and flexible network connectivity options with 1 10 GbE RJ 45 10 GbE SFP and 10 25 GbE SF...

Page 2: ...torage resources Native HCI security solution with two factor authentication SecurID and CAC and data at rest encryption that does not require self encrypting drives SEDs Stretched cluster with local and site failure protection between two geographically dispersed sites for higher level of availability with near zero downtime Centralized management with provisioning administering and monitoring vi...

Page 3: ...th XClarity Controller access One USB 3 0 port A Power button Status LEDs that display the status of the system The following figure shows the rear view of the VX3320 appliance Figure 3 VX3320 rear view The rear of the VX3320 appliance includes the following components Up to three PCIe expansion slots One LOM card slot One 1 GbE port for XClarity Controller One VGA port Two USB 3 0 ports Up to two...

Page 4: ...TA SSDs up to 7 68 TB NVMe PCIe 3 0 x4 SSDs up to 6 4 TB Capacity drives 12 Gbps SAS HDDs up to 2 4 TB 12 Gbps NL SAS HDDs up to 2 TB 12 Gbps SAS SSDs up to 7 68 TB 6 Gbps SATA SSDs up to 7 68 TB Note The withdrawn VX3320 7Y13 does not support NVMe PCIe SSDs Note All cache drives in the appliance must be of the same model and capacity All capacity drives in the appliance must be of the same model ...

Page 5: ...from Lenovo or provided by the customer VMware vSphere Standard Enterprise Plus or ROBO VMware Horizon Standard optional VMware vCenter Server Foundation or Standard Hypervisors 7Y13 VMware ESXi 6 5 U1 factory preload 7Y93 VMware ESXi 6 5 U2 6 5 U3 6 7 6 7 U1 6 7 U2 or 6 7 U3 factory preload Warranty and support Three or five year customer replaceable unit and onsite limited hardware warranty with...

Page 6: ...ns Description Part number Feature code Quantity min max Intel Xeon Bronze processors Intel Xeon Bronze 3104 6C 85W 1 7GHz Processor 7XG7A05528 AWEJ 1 2 Intel Xeon Bronze 3106 8C 85W 1 7GHz Processor 7XG7A05526 AWEH 1 2 Intel Xeon Silver processors Intel Xeon Silver 4108 8C 85W 1 8GHz Processor 7XG7A05527 AWEG 1 2 Intel Xeon Silver 4109T 8C 70W 2 0GHz Processor 7XG7A05530 AWET 1 2 Intel Xeon Silve...

Page 7: ...0GHz Processor 7XG7A05549 AWDR 1 2 Intel Xeon Platinum 8156 4C 105W 3 6GHz Processor 7XG7A05548 AWDL 1 2 Intel Xeon Platinum 8158 12C 150W 3 0GHz Processor 7XG7A05569 AWDS 1 2 Intel Xeon Platinum 8160 24C 150W 2 1GHz Processor 7XG7A05568 AWDP 1 2 Intel Xeon Platinum 8160M 24C 150W 2 1GHz Processor 7XG7A05567 AWDQ 1 2 Intel Xeon Platinum 8160T 24C 150W 2 1GHz Processor 7XG7A05566 AWEK 1 2 Intel Xeo...

Page 8: ... s 150 W Yes Yes Yes Yes 6138 2 0 3 7 GHz 20 40 27 5 MB 2666 MHz 768 GB 10 4 GT s 125 W Yes Yes Yes Yes 6138T 2 0 3 7 GHz 20 40 27 5 MB 2666 MHz 768 GB 10 4 GT s 125 W Yes Yes Yes Yes 6140 2 3 3 7 GHz 18 36 24 75 MB 2666 MHz 768 GB 10 4 GT s 140 W Yes Yes Yes Yes 6140M 2 3 3 7 GHz 18 36 24 75 MB 2666 MHz 1 5 TB 10 4 GT s 140 W Yes Yes Yes Yes 6142 2 6 3 7 GHz 16 32 22 MB 2666 MHz 768 GB 10 4 GT s ...

Page 9: ... DIMMs ADDDC for x4 based memory DIMMs Gold and Platinum processors only Patrol scrubbing Demand scrubbing Single Device Data Correction SDDC works only in the independent channel mode the default operational mode and supports only x4 based memory DIMMs Adaptive Double Device Data Correction ADDDC works with x4 based memory DIMMs and requires two DIMM ranks per channel Intel Xeon Gold or Platinum ...

Page 10: ...rvisor boot volume The following table lists M 2 drive selection options for the hypervisor boot volume Table 8 Drive options for hypervisor boot volume Description Part number Feature code Quantity ThinkSystem M 2 128GB SATA 6Gbps Non Hot Swap SSD 7N47A00130 AUUV 2 ThinkSystem M 2 5100 240GB SATA 6Gbps Non Hot Swap SSD 4XB7A14049 B5S4 2 ThinkSystem M 2 5300 240GB SATA 6Gbps Non Hot Swap SSD 4XB7A...

Page 11: ...2TB Performance SAS 12Gb Hot Swap SSD 4XB7A10232 B4Y7 1 1 SSD selection Cache tier SAS 12Gb SSDs PM1645 Mainstream ThinkSystem 2 5 PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD 4XB7A13653 B4A0 1 1 ThinkSystem 2 5 PM1645 1 6TB Mainstream SAS 12Gb Hot Swap SSD 4XB7A13654 B4A1 1 1 ThinkSystem 2 5 PM1645 3 2TB Mainstream SAS 12Gb Hot Swap SSD 4XB7A13655 B4A2 1 1 SSD selection Cache tier SAS 12Gb SSDs ...

Page 12: ...selection Capacity tier SAS 12Gb HDDs ThinkSystem 2 5 900GB 10K SAS 12Gb Hot Swap 512n HDD 7XB7A00026 AUM0 2 7 ThinkSystem 2 5 900GB 15K SAS 12Gb Hot Swap 512e HDD 7XB7A00023 AULX 2 7 ThinkSystem 2 5 1 2TB 10K SAS 12Gb Hot Swap 512n HDD 7XB7A00027 AUM1 2 7 ThinkSystem 2 5 1 8TB 10K SAS 12Gb Hot Swap 512e HDD 7XB7A00028 AUM2 2 7 ThinkSystem 2 5 2 4TB 10K SAS 12Gb Hot Swap 512e HDD 7XB7A00069 B0YS 2...

Page 13: ...a 7 68TB Entry SAS 12Gb Hot Swap SSD 4XB7A17055 B91D 1 1 Cache tier SATA 6Gb SSDs 5300 Mainstream ThinkSystem 2 5 5300 480GB Mainstream SATA 6Gb Hot Swap SSD 4XB7A17088 B8HY 1 1 ThinkSystem 2 5 5300 960GB Mainstream SATA 6Gb Hot Swap SSD 4XB7A17089 B8J6 1 1 ThinkSystem 2 5 5300 1 92TB Mainstream SATA 6Gb Hot Swap SSD 4XB7A17090 B8JE 1 1 ThinkSystem 2 5 5300 3 84TB Mainstream SATA 6Gb Hot Swap SSD ...

Page 14: ...ThinkSystem 2 5 PM1643a 3 84TB Entry SAS 12Gb Hot Swap SSD 4XB7A17054 B91C 2 7 ThinkSystem 2 5 PM1643a 7 68TB Entry SAS 12Gb Hot Swap SSD 4XB7A17055 B91D 2 7 Capacity tier SATA 6Gb SSDs 5300 Mainstream ThinkSystem 2 5 5300 480GB Mainstream SATA 6Gb Hot Swap SSD 4XB7A17088 B8HY 2 7 ThinkSystem 2 5 5300 960GB Mainstream SATA 6Gb Hot Swap SSD 4XB7A17089 B8J6 2 7 ThinkSystem 2 5 5300 1 92TB Mainstream...

Page 15: ...ntity per drive group min max Configuration notes The VX3320 appliance supports up to 3 drive groups Each drive group contains 1 cache drive and up to 7 capacity drives depending on the quantity of the drive groups 1 drive group From 2 to 7 capacity drives 2 drive groups From 2 to 4 capacity drives in each group 3 drive groups 2 capacity drives in each group The quantity of the capacity drives in ...

Page 16: ...SR570 SR630 x8 x16 PCIe LP LP Riser 1 Kit 7XH7A02682 AUWC 1 ThinkSystem SR530 SR570 SR630 x8 x16 PCIe LP FH Riser 1 Kit 7XH7A05893 None 1 ThinkSystem SR630 x8ML2 x16 PCIe LP LP Riser 1 Kit 7XH7A02683 AUWE 1 ThinkSystem SR630 x8ML2 x16 PCIe LP FH Riser 1 Kit 7XH7A05894 None 1 ThinkSystem SR630 x16ML2 x8 PCIe LP LP Riser 1 Kit 7XH7A02684 AUWD 1 ThinkSystem SR630 x16ML2 x8 PCIe LP FH Riser 1 Kit 7XH7...

Page 17: ...ight and low profile PCIe x8 and x16 slots supplied by the Riser Cards 1 and 2 One of the network adapter options is required for selection Additional ports can be selected if needed If two PCIe network adapters are selected they must be of the same model The withdrawn VX3320 7Y13 appliance does not support 10 25 GbE SFP28 network adapters Supported transceivers or DAC cables should be purchased f...

Page 18: ...assive SFP DAC Cable 00D6288 A3RG Lenovo 1m Passive SFP DAC Cable 90Y9427 A1PH Lenovo 1 5m Passive SFP DAC Cable 00AY764 A51N Lenovo 2m Passive SFP DAC Cable 00AY765 A51P Lenovo 3m Passive SFP DAC Cable 90Y9430 A1PJ Lenovo 5m Passive SFP DAC Cable 90Y9433 A1PK Lenovo 7m Passive SFP DAC Cable 00D6151 A3RH Active SFP DAC cables for 10 GbE SFP adapters Lenovo 1m Active DAC SFP Cable 00VX111 AT2R Leno...

Page 19: ...AV1J Lenovo 20m 25G SFP28 Active Optical Cable 7Z57A03545 AV1K Not supported with the Intel XXV710 DA2 PCIe 25Gb 2 Port SFP28 Ethernet Adapter 7XC7A05523 Power supplies and cables The VX3320 appliances can be configured with one or two power supplies The following table lists the power supply options that are available for selection Table 18 Power supplies Description Part number Feature code Quan...

Page 20: ... Rack Power Cable 39Y7932 6263 4 3m 13A 125V 10A 250V C13 to IEC 320 C14 Rack Power Cable 4L67A08371 6583 Line cords Argentina 2 8m 10A 250V C13 to IRAM 2073 Line Cord 39Y7930 6222 Argentina 4 3m 10A 250V C13 to IRAM 2073 Line Cord 81Y2384 6492 Australia New Zealand 2 8m 10A 250V C13 to AS NZS 3112 Line Cord 39Y7924 6211 Australia New Zealand 4 3m 10A 250V C13 to AS NZS 3112 Line Cord 81Y2383 6574...

Page 21: ...m 15A 125V C13 to CNS 10917 3 Line Cord 81Y2388 6530 United Kingdom 2 8m 10A 250V C13 to BS 1363 A Line Cord 39Y7923 6215 United Kingdom 4 3m 10A 250V C13 to BS 1363 A Line Cord 81Y2377 6577 United States 2 8m 10A 125V C13 to NEMA 5 15P Line Cord 90Y3016 6313 United States 2 8m 10A 250V C13 to NEMA 6 15P Line Cord 46M2592 A1RF United States 2 8m 13A 125V C13 to NEMA 5 15P Line Cord 00WH545 6401 Un...

Page 22: ...installed only no field upgrade Configuration note One of the rail kits is required for selection The following table summarizes the features of the rail kits that are available for selection Table 21 Rail kit features and specifications summary Feature Tool less Slide Rail Without CMA With CMA Part number 7M27A05702 7M27A05701 CMA 7M27A05699 Included Rail length 730 mm 28 74 in 807 mm 31 8 in Rai...

Page 23: ...e VMware vSAN licenses for VX Series appliances from Lenovo For VMware vSphere and vCenter Server customers can use the existing VMware software licenses and active support contracts or they can purchase software licenses and support from Lenovo or VMware Lenovo offers the following VMware software license and support options for ThinkAgile VX Series appliances VMware vSAN License and Subscription...

Page 24: ...uantity of VM based licenses is specified based on VM requirements The quantity of CCU based licenses is specified based on the concurrent user requirements Lenovo ThinkAgile VX3320 Appliance Xeon SP Gen 1 withdrawn product 24 ...

Page 25: ...Feature code VMware Virtual SAN 6 Standard B2Q7 VMware Virtual SAN 6 Advanced B2Q8 VMware Virtual SAN 6 Enterprise B2Q9 VMware Virtual SAN 6 for Remote Office Branch Office 25 VM Pack B2QA The following table lists the VMware vSAN License and Subscription options that are derived by the configurator based on the selected quantity of processors software edition and warranty period Table 25 VMware v...

Page 26: ... license Two or more nodes can be used in a cluster under the ROBO license however the maximum number of VMs at the location must not exceed 25 Requires All Flash configurations hybrid configurations not supported VMware vSphere License and Subscription Lenovo offers the following VMware vSphere License and Subscription options that can be purchased for ThinkAgile VX Series appliances VMware vSphe...

Page 27: ...here 6 Remote Office Branch Office Standard VMware vSphere 6 Remote Office Branch Office Standard 25 VM Pack w 3Yr S S 7S06003KWW B2AY VMware vSphere 6 Remote Office Branch Office Standard 25 VM Pack w 5Yr S S 7S06006VWW B2E8 vSphere 6 Remote Office Branch Office Advanced VMware vSphere 6 Remote Office Branch Office Advanced 25 VM Pack w 3Yr S S 7S06003LWW B2AZ VMware vSphere 6 Remote Office Branc...

Page 28: ... ROBO Standard ROBO Advanced Requires vCenter Server Standard VMware HCI Kit License and Subscription Lenovo offers the following VMware HCI license bundles for ThinkAgile VX Series appliances that include both vSphere and vSAN License and Subscription options VMware HCI Kit Essentials For 3 nodes vSphere Essentials Plus vSAN Standard VMware HCI Kit Standard Per CPU vSphere Standard vSAN Standard ...

Page 29: ...CI Kit Enterprise Per CPU w 3Yr Support 7S060059WW B2CN VMware HCI Kit Enterprise Per CPU w 5Yr Support 7S06008KWW B2FY VMware Horizon 7 License and Subscription Lenovo offers the following VMware Horizon 7 License and Subscription options for Virtual Desktop Infrastructure VDI deployments that can be purchased for the ThinkAgile VX Series appliances VMware Horizon 7 Standard delivers simple power...

Page 30: ... Concurrent User Pack w 3Yr Support 7S06003ZWW B2BC VMware Horizon 7 Advanced 10 Concurrent User Pack w 5Yr Support 7S060079WW B2EN VMware Horizon 7 Advanced 10 Named User Pack w 3Yr Support 7S060041WW B2BE VMware Horizon 7 Advanced 10 Named User Pack w 5Yr Support 7S06007BWW B2EQ VMware Horizon 7 Advanced 100 Concurrent User Pack w 3Yr Support 7S060040WW B2BD VMware Horizon 7 Advanced 100 Concurr...

Page 31: ...ted software platform that automates the deployment and lifecycle management of a complete software defined data center SDDC in hyperconverged environments The following Cloud Foundation License and Subscription options are offered Cloud Foundation Basic includes vSphere Enterprise Plus vSAN Advanced NSX Data Center Professional and SDDC Manager Cloud Foundation Standard includes vSphere Enterpris...

Page 32: ... Foundation Advanced Per CPU w 3Y Subscription and Support 7S0600DRWW S1SF VMware Cloud Foundation Advanced Per CPU w 5Y Subscription and Support 7S0600DSWW S1SG VMware Cloud Foundation Enterprise VMware Cloud Foundation Enterprise Per CPU w 3Y Subscription and Support 7S0600DUWW S1SJ VMware Cloud Foundation Enterprise Per CPU w 5Y Subscription and Support 7S0600DVWW S1SK VMware Cloud Foundation f...

Page 33: ...se purchased from Lenovo includes three or five years of support and subscription matches the duration of the selected hardware warranty period VMware vCenter Server selection options for the ThinkAgile VX Series appliances are listed in the following table Table 37 VMware vCenter Server selection options Description Feature code VMware vCenter Server 6 Foundation B2Q6 VMware vCenter Server 6 Stan...

Page 34: ...ature code vSAN 6 VMware vSAN 6 Standard for 1 Processor w 1Yr Support 7S06001HWW B28W VMware vSAN 6 Advanced for 1 Processor w 1Yr Support 7S06001MWW B290 VMware vSAN 6 Enterprise for 1 Processor w 1Yr Support 7S06001RWW B294 VMware vSAN 6 Enterprise Plus for 1 Processor w 1Y Support 7S0600FRWW S226 vSAN 6 for Remote Office Branch Office VMware vSAN 6 Standard for Rmt Off Brnch Off 25VM Pk w 1Yr ...

Page 35: ...ck Per CCU w 1Y S S 7S0600D3WW S1RT VCF for VDI SDDC Mgr and NSX DC ADV w o Horizon ENT 10 pack per CCU w 1Y S S 7S0600DCWW S1S2 VCF for VDI SDDC Mgr and NSX DC ADV w o Horizon ENT 100 pack per CCU w 1Y S S 7S0600D9WW S1RZ VCF for VDI SDDC Mgr and NSX DC ENT w o Horizon ENT 10 pack Per CCU w 1Y S S 7S0600DJWW S1S8 VCF for VDI SDDC Mgr and NSX DC ENT w o Horizon ENT 100 pack Per CCU w 1Y S S 7S0600...

Page 36: ...rity Administrator is a centralized systems management solution that helps administrators deliver infrastructure faster This solution integrates easily with Lenovo x86 servers appliances certified nodes Top of Rack Ethernet switches and storage systems providing automated agent less discovery inventory monitoring and alerts across multiple systems In addition some managed endpoints support firmwar...

Page 37: ...vides a stand alone web based agent less power management console that provides real time data and enables you to observe plan and manage power and cooling for Lenovo servers appliances and certified nodes Using built in intelligence XClarity Energy Manager identifies server power consumption trends and ideal power settings and it performs cooling analysis so that customers can define and optimize...

Page 38: ...ient temperature by 1 C for every 175 m 574 ft increase in altitude ASHRAE Class A2 10 C 35 C 50 F 95 F for altitudes above 900 m 2 953 ft decrease the maximum ambient temperature by 1 C for every 300 m 984 ft increase in altitude Non operating 5 C 45 C 41 F 113 F Storage 40 C 60 C 40 F 140 F Maximum altitude 3 050 m 10 000 ft Humidity Operating ASHRAE Class A4 8 90 non condensing maximum dew poin...

Page 39: ...17 3 3 IEC 60950 1 CB Certificate and CB Test Report Europe CE Mark EN55022 Class A EN60950 1 EN55024 EN61000 3 2 EN61000 3 3 CISPR 22 Class A Germany TUV GS EN60950 1 IEC60950 1 EK1 ITB2000 Reduction of Hazardous Substances ROHS Energy Star 3 0 excluding configurations with Bronze 3104 Silver 4112 Gold 5122 or Platinum 8156 processors Note For more information on the Energy Star 3 0 certification...

Page 40: ...check error logs verify firmware and operating system device driver levels and software as needed Lenovo will also maintain records of latest patches critical updates and firmware levels to ensure customer s systems are providing business value through optimized performance Technical Account Management TAM A Lenovo Technical Account Manager helps customers optimize operations of their data centers...

Page 41: ...er Solution Configurator DCSC http dcsc lenovo com services Lenovo Services Availability Locator https lenovolocator com For service definitions region specific details and service limitations refer to the following documents Lenovo Statement of Limited Warranty for Infrastructure Solutions Group ISG Servers and System Storage http pcsupport lenovo com us en solutions ht503310 Lenovo Data Center S...

Page 42: ...rnet LAN switches that are offered by Lenovo that can be used with the ThinkAgile VX3320 appliances for network connectivity Table 41 Ethernet LAN switches Description Part number 1 Gb Ethernet switches Out of band hardware management or 1 GbE host connectivity Lenovo ThinkSystem NE0152T RackSwitch Rear to Front 7Y810011WW Lenovo ThinkSystem NE0152TO RackSwitch Rear to Front ONIE 7Z320O11WW Lenovo...

Page 43: ...no sidewall compartments 1YR Warranty 7D2B0001WW 12U 1200mm Deep Micro Datacenter Rack no sidewall compartments 3YR Warranty 7D2N0001WW 18U 1200mm Deep Micro Datacenter Rack no sidewall compartments 1YR Warranty 7D2C0001WW 18U 1200mm Deep Micro Datacenter Rack no sidewall compartments 3YR Warranty 7D2P0001WW 25U S2 Standard Rack 1000 mm deep 2 sidewall compartments 93072RX 25U Static S2 Standard R...

Page 44: ...ored DPI PDU without line cord 46M4004 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P Gnd line cord 46M4005 Ultra Density Enterprise PDUs 9x IEC 320 C13 3x IEC 320 C19 outlets Ultra Density Enterprise C19 C13 PDU Module without line cord 71762NX Ultra Density Enterprise C19 C13 PDU 60A 208V 3ph with IEC 309 3P Gnd line cord 71763NU C13 Enterprise PDUs 12x IEC 320 C13 outlets DPI ...

Page 45: ...55943AX RT3kVA 2U Rack or Tower UPS 200 240VAC 8x IEC 320 C13 10A 1x IEC 320 C19 16A outlets 55943KX RT5kVA 3U Rack or Tower UPS 200 240VAC 8x IEC 320 C13 10A 2x IEC 320 C19 16A outlets 55945KX RT6kVA 3U Rack or Tower UPS 200 240VAC 8x IEC 320 C13 10A 2x IEC 320 C19 16A outlets 55946KX RT8kVA 6U Rack or Tower UPS 200 240VAC 4x IEC 320 C19 16A outlets 55948KX RT11kVA 6U Rack or Tower UPS 200 240VAC...

Page 46: ...ution we can consolidate everything into a single invoice Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly As a premier client you have a dedicated finance specialist who manages your account through its life from first invoice through asset return or purchase This specialist develops an in depth understand...

Page 47: ... for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties All information c...

Page 48: ...kSwitch ThinkAgile ThinkSystem TruDDR4 XClarity The following terms are trademarks of other companies Intel and Xeon are trademarks of Intel Corporation or its subsidiaries Linux is the trademark of Linus Torvalds in the U S and other countries Microsoft PowerShell SQL Server SharePoint Skype Windows PowerShell and Windows are trademarks of Microsoft Corporation in the United States other countrie...

Reviews: