12. Install the screw that secures the new power switch module to the front bezel.

13. Install the 21 screws to secure the main bracket to the front bezel.

14. Reconnect all the cables that were disconnected.

15. Go to “Completing the parts replacement” on page 111.

Replacing the front panel control board

Attention

Do not open your computer or attempt any repair before reading and understanding the “Important safety
information” in the

ThinkCentre Safety and Warranty Guide

that came with your computer. To obtain a copy

of the

ThinkCentre Safety and Warranty Guide

, go to:

http://www.lenovo.com/support

This section provides instructions on how to replace the front panel control board.

To replace the front panel control board, do the following:

1. Remove all media from the drives and turn off all attached devices and the computer. Then, disconnect

all power cords from electrical outlets and disconnect all cables that are connected to the computer.

2. Place a soft, clean towel or cloth on the desk or surface. Hold the sides of your computer and gently lay

it down so that the screen is against the surface and the cover is facing up.

3. Remove the computer cover. See “Removing the computer cover” on page 71.

4. Locate the front panel control board in the computer. See “FRU locations” on page 67.

5. Remove the 21 screws that secure the main bracket to the front bezel.

6. Note the locations of all cable connections that prevent you from lifting the computer main bracket, and

disconnect all cables. See “System board parts and connectors” on page 69.

7. Lift the main bracket off the front bezel.

8. Remove the three screws

1

that secure the front panel control board to the front bezel.

Chapter 8

.

Replacing FRUs

105

Summary of Contents for ThinkCentre M70z

Page 1: ...ThinkCentre Hardware Maintenance Manual Machine Types 7570 7577 7578 7580 7583 7584 7589 7594 7595 7597 and 7598 ...

Page 2: ......

Page 3: ...ThinkCentre Hardware Maintenance Manual Machine Types 7570 7577 7578 7580 7583 7584 7589 7594 7595 7597 and 7598 ...

Page 4: ...arranty Guide and Appendix A Notices on page 197 Fourth Edition June 2011 Copyright Lenovo 2010 2011 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software are delivered pursuant a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 ...

Page 5: ...rtup device sequence 40 Exiting the Setup Utility program 40 Chapter 7 Symptom to FRU Index 41 Hard disk drive boot error 41 Power Supply Problems 41 Diagnostic error codes 42 Beep symptoms 59 POST error codes 59 Miscellaneous error conditions 60 Undetermined problems 62 Chapter 8 Replacing FRUs 63 Locating connectors controls and indicators on the front of your computer 64 Using your computer in ...

Page 6: ... Recovery CD 189 Windows 7 Starter 32 Recovery CD 189 Windows 7 Ultimate 32 Recovery CD 191 Chapter 10 Additional Service Information 193 Security features 193 Hardware controlled Passwords 193 Operating system password 193 Vital product data 193 BIOS levels 193 Flash update procedures 193 Updating flashing the BIOS from a disc 193 Updating flashing the BIOS from your operating system 194 Recoveri...

Page 7: ...t document avant d exécuter les instructions Lesen Sie unbedingt alle Hinweise vom Typ ACHTUNG oder VORSICHT in dieser Dokumentation bevor Sie irgendwelche Vorgänge durchführen Leggere le istruzioni introdotte da ATTENZIONE e PERICOLO presenti nel manuale prima di eseguire una qualsiasi delle istruzioni Certifique se de ler todas as instruções de cuidado e perigo neste manual antes de executar qua...

Page 8: ...nt parts RoHS compliant ThinkCentre parts have unique FRU part numbers Before or after June 2006 failed RoHS compliant parts must always be replaced using RoHS compliant FRUs so only the FRUs identified as compliant in the system hardware maintenance manual or direct substitutions for those FRUs can be used Products marketed before June 2006 Products marketed after June 2006 Current or original pa...

Page 9: ... other people will not trip over it Do not wear loose clothing that can be trapped in the moving parts of a machine Ensure that your sleeves are fastened or rolled up above your elbows If your hair is long fasten it Insert the ends of your necktie or scarf inside clothing or fasten it with a nonconductive clip approximately 8 centimeters 3 inches from the end Do not wear jewelry chains metal frame...

Page 10: ...re must be a complete circuit to cause electrical shock By observing the above rule you may prevent a current from passing through your body When using a tester set the controls correctly and use the approved probe leads and accessories for that tester Stand on suitable rubber mats obtained locally if necessary to insulate you from grounds such as metal floor strips and machine frames Observe the ...

Page 11: ...re ground continuity for 0 1 ohm or less between the external ground pin and frame ground b The power cord should be the appropriate type as specified in the parts listings c Insulation must not be frayed or worn 4 Remove the cover 5 Check for any obvious alterations Use good judgment as to the safety of any alterations 6 Check inside the unit for any obvious unsafe conditions such as metal filing...

Page 12: ...rated computers Grounding requirements Electrical grounding of the computer is required for operator safety and correct system function Proper grounding of the electrical outlet can be verified by a certified electrician Safety notices multi lingual translations The caution and danger safety notices in this section are provided in the following languages English Arabic Brazilian Portuguese Chinese...

Page 13: ... system has a module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not Throw or immerse into water Heat to more than 100 C 212 F Repair or disassemble Dispose of the battery as required by local ordinances or regulations CAUTION When laser products such...

Page 14: ...e device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 1 2 8 ThinkCentre Hardware Maintenance Manual ...

Page 15: ...Chapter 2 Safety information 9 ...

Page 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...

Page 17: ... ou abrir tampas deste produto ou de dispositivos conectados Para Conectar Para Desconectar 1 DESLIGUE Tudo 2 Primeiramente conecte todos os cabos aos dispositivos 3 Conecte os cabos de sinal aos conectores 4 Conecte os cabos de alimentação às tomadas 5 LIGUE os dispositivos 1 DESLIGUE Tudo 2 Primeiramente remova os cabos de alimentação das tomadas 3 Remova os cabos de sinal dos conectores 4 Remov...

Page 18: ...ção a laser quando aberto Não olhe diretamente para o feixe a olho nu ou com instrumentos ópticos e evite exposição direta ao feixe 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs CUIDADO Utilize procedimentos de segurança para levantar equipamentos CUIDADO O botão de controle de alimentação do dispositivo e o botão para ligar desligar da fonte de alimentação não desligam a corrente elétrica fornecida...

Page 19: ...Chapter 2 Safety information 13 ...

Page 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...

Page 21: ...Chapter 2 Safety information 15 ...

Page 22: ...ilisez qu une seule main pour connecter ou déconnecter les câbles d interface Ne mettez jamais un équipement sous tension en cas d incendie ou d inondation ou en présence de dommages matériels Avant de retirer les carters de l unité mettez celle ci hors tension et déconnectez ses cordons d alimentation ainsi que les câbles qui la relient aux réseaux aux systèmes de télécommunication et aux modems ...

Page 23: ...inappropriée Ne pas la jeter à l eau l exposer à des températures supérieures à 100 C chercher à la réparer ou à la démonter Ne pas mettre la pile à la poubelle Pour la mise au rebut se reporter à la réglementation en vigueur ATTENTION Si des produits à laser tels que des unités de CD ROM de DVD ROM des unités à fibres optiques ou des émetteurs sont installés prenez connaissance des informations s...

Page 24: ...en anliegen Aus Sicherheitsgründen Bei Gewitter an diesem Gerät keine Kabel anschließen oder lösen Ferner keine Installations Wartungs oder Rekonfigurationsarbeiten durchführen Gerät nur an eine Schutzkontaktsteckdose mit ordnungsgemäß geerdetem Schutzkontakt anschließen Alle angeschlossenen Geräte ebenfalls an Schutzkontaktsteckdosen mit ordnungsgemäß geerdetem Schutzkontakt anschließen Die Signa...

Page 25: ...hiumbatterie nur durch eine Batterie mit der Teilenummer 45C1566 oder eine gleichwertige vom Hersteller empfohlene Batterie ersetzen Enthält das System ein Modul mit einer Lithiumbatterie dieses nur durch ein Modul desselben Typs und von demselben Hersteller ersetzen Die Batterie enthält Lithium und kann bei unsachgemäßer Verwendung Handhabung oder Entsorgung explodieren Die Batterie nicht mit Was...

Page 26: ...eben der Maschine beachten ACHTUNG Mit dem Netzschalter an der Einheit und am Netzteil wird die Stromversorgung für die Einheit nicht unterbrochen Die Einheit kann auch mit mehreren Netzkabeln ausgestattet sein Um die Stromversorgung für die Einheit vollständig zu unterbrechen müssen alle zum Gerät führenden Netzkabel vom Netz getrennt werden 1 2 20 ThinkCentre Hardware Maintenance Manual ...

Page 27: ...Chapter 2 Safety information 21 ...

Page 28: ...legare qualsiasi cavo oppure effettuare l installazione la manutenzione o la riconfigurazione del prodotto durante un temporale Collegare tutti i fili elettrici a una presa di alimentazione correttamente cablata e dotata di messa a terra Collegare alle prese elettriche appropriate tutte le apparecchiature che verranno utilizzate per questo prodotto 22 ThinkCentre Hardware Maintenance Manual ...

Page 29: ...ndo si sostituisce la batteria al litio utilizzare solo il Numero parte 45C1566 o un tipo di batteria equivalente consigliato dal produttore Se sul sistema è presente un modulo che contiene una batteria al litio sostituirlo solo con un tipo di modulo dello stesso tipo della stessa casa di produzione La batteria contiene litio e può esplodere se usata maneggiata o smaltita in modo non corretto Non ...

Page 30: ...kg ATTENZIONE Prestare attenzione nel sollevare l apparecchiatura ATTENZIONE Il pulsante di controllo dell alimentazione presente sull unità e l interruttore dell alimentatore non disattivano l alimentazione corrente fornita all unità E possibile che l unità disponga di più cavi di alimentazione Per disattivare l alimentazione dall unità accertarsi che tutti i cavi di alimentazione siano scollegat...

Page 31: ...Chapter 2 Safety information 25 ...

Page 32: ...ste producto durante una tormenta eléctrica Conecte todos los cables de alimentación a tomas de corriente debidamente cableadas y conectadas a tierra Cualquier equipo que se conecte a este producto también debe conectarse a tomas de corriente debidamente cableadas Siempre que sea posible utilice una sola mano para conectar o desconectar los cables de señal No encienda nunca un equipo cuando hay se...

Page 33: ...ya una batería de litio utilice solamente una batería número de pieza 45C1566 u otra de tipo equivalente recomendada por el fabricante Si su sistema dispone de un módulo que contiene una batería de litio reemplácelo sólo con el mismo tipo de módulo del mismo fabricante La batería contiene litio y puede explotar si no se utiliza manipula o desecha correctamente No debe Arrojarla al agua o sumergirl...

Page 34: ...dopte procedimientos seguros al levantar el equipo PRECAUCIÓN El botón de control de alimentación del dispositivo y el interruptor de alimentación de la fuente de alimentación no desconectan la corriente eléctrica suministrada al dispositivo Además el dispositivo podría tener más de un cable de alimentación Para suprimir toda la corriente eléctrica del dispositivo asegúrese de que todos los cables...

Page 35: ...einstalled with the Windows 7 operating system from Lenovo Lenovo ThinkVantage Toolbox The Lenovo ThinkVantage Toolbox program helps you maintain your computer improve computing security diagnose computer problems get familiar with the innovative technologies provided by Lenovo and get more information about your computer For more information see Lenovo ThinkVantage Toolbox on page 33 Additional i...

Page 36: ...5 degrees from the vertical Frame stand Tilt adjustment 15 degrees to 45 degrees from the vertical Environment Air temperature Operating 10 to 35 50 to 95 Non operating 20 to 60 4 to 140 with package Humidity Operating 20 to 80 10 per hour non condensing Non operating 20 to 80 10 per hour non condensing Altitude Operating 50 to 10 000 ft 15 2 to 3 048 m Non operating 50 to 35 000 ft 15 2 to 10 668...

Page 37: ...error codes Listen for beep codes Look for readable instructions or a main menu on the display If you did not receive the correct response proceed to step 6 on page 31 If you do receive the correct response proceed to step 7 on page 31 6 Look at the following conditions and follow the instructions If you hear beep codes during POST go to Beep symptoms on page 59 If the computer displays a POST err...

Page 38: ...d identical only if they 1 Are the exact machine type and models 2 Have the same BIOS level 3 Have the same adapters attachments in the same locations 4 Have the same address jumpers terminators cabling 5 Have the same software versions and levels 6 Have the same Diagnostic Diskettes version 7 Have the same configuration options set in the system 8 Have the same setup for the operating system cont...

Page 39: ...puter You can use the diagnostics feature of the Lenovo ThinkVantage Toolbox program to test devices diagnose computer problems create bootable diagnostic media update system drivers and view system information To run the Lenovo ThinkVantage Toolbox program on the Windows 7 operating system click Start All Programs Lenovo ThinkVantage Tools System Health and Diagnostics Follow the instructions on ...

Page 40: ...e diagnostic tests Using the cursor movement keys highlight Run Normal Test or Run Quick Test from the Diagnostics menu and then press Enter This automatically runs a pre defined group of tests from each test category Run Normal Test runs a more extensive set of tests than does Run Quick Test and takes longer to complete Press F5 to automatically run all selected tests in all categories From withi...

Page 41: ...mat utilities Quick Erase Hard Drive Full Erase Hard Drive Quick Erase Hard Drive provides a DOS utility that performs the following Destroys the Master Boot Record MBR on the hard drive Destroys all copies of the FAT Table on all partitions both the master and backup Destroys the partition table Provides messages that warn the user that this is a non recoverable process Full Erase Hard Drive prov...

Page 42: ... as a failed test To view details of a failure or to view a list of test results use the following procedure from any test category screen 1 Press F3 to activate the log file 2 Press F3 again to save the file to diskette or press F2 to print the file 36 ThinkCentre Hardware Maintenance Manual ...

Page 43: ...y The Setup Utility program opens Note If a password has been set the Setup Utility program menu will not be displayed until you type the correct password For more information see Using passwords on page 37 Viewing or changing settings The Setup Utility program menu lists various items about the system configuration settings To view or change the settings start the Setup Utility program See Starti...

Page 44: ... any configuration settings you must use your administrator password Power on password After you have set a power on password using the Set Power On Password option a password prompt is displayed each time you turn on the computer You cannot use the computer until a valid password is typed in For more information about how to set a password see Setting changing or deleting a password on page 38 Ha...

Page 45: ...Esc to return to the Setup Utility program main menu You might have to press Esc several times 6 Press F10 to save the new settings and exit the Setup Utility program Notes a If you do not want to save the new settings select Exit Discard Changes and Exit b If you want to return to the default settings press F9 or select Exit Load Optimal Defaults Selecting a startup device If your computer does n...

Page 46: ...ht have to press Esc several times 6 Press F10 to save the new settings and exit the Setup Utility program Notes a If you do not want to save the new settings select Exit Discard Changes and Exit b If you want to return to the default settings press F9 or select Exit Load Optimal Defaults Exiting the Setup Utility program After you finish viewing or changing settings press Esc to return to the Set...

Page 47: ...d disk drive boot error can have the following causes Error FRU Action The start up drive is not in the boot sequence in configuration Check the configuration and ensure the start up drive is in the boot sequence No operating system installed on the boot drive Install an operating system on the boot drive The boot sector on the startup drive is corrupted The drive must be formatted Do the followin...

Page 48: ... Setup error 1 Run the Setup Utility program 2 Flash the system See Flash update procedures on page 193 3 System board 000 034 XXX BIOS Buffer Allocation failure 1 Reboot the system 2 Flash the system See Flash update procedures on page 193 3 Run memory test 4 System board 000 035 XXX BIOS Reset Condition detected 1 Flash the system See Flash update procedures on page 193 2 System board 000 036 XX...

Page 49: ...em board 000 270 XXX BIOS ACPI failure 1 Flash the system See Flash update procedures on page 193 2 System board 001 000 XXX System Test Passed No action 001 00X XXX System Error System board 001 01X XXX System Error System board 001 024 XXX System Addressing test failure System board 001 025 XXX System Checksum Value error 1 Flash the system See Flash update procedures on page 193 2 System board ...

Page 50: ...warning statement 4 Replace the component under test 001 198 XXX System test aborted 1 If a component is called out make sure it is connected and or enabled See Chapter 6 Using the Setup Utility program on page 37 2 Flash the system and retest See Flash update procedures on page 193 3 Go to Undetermined problems on page 62 001 199 XXX System test failed cause unknown 1 Go to Undetermined problems ...

Page 51: ... 001 282 XXX System IRQ15 failure 1 Device on IRQ15 2 System board 001 286 XXX 001 287 XXX 001 288 XXX System Timer failure System board 001 292 XXX System CMOS RAM error 1 Run the Setup Utility program and re test 2 System board 001 293 XXX System CMOS Battery 1 CMOS Battery 2 System board 001 298 XXX System RTC date time update failure 1 Flash the system See Flash update procedures on page 193 2...

Page 52: ...ard if installed 2 System board 005 195 XXX Video Test aborted by user Information only Restart the test if necessary 005 196 XXX Video test halt error threshold exceeded 1 Press F3 to review the log file 2 Restart the test to reset the log file 005 197 XXX Video test warning 1 Make sure the component that is called out is connected and or enabled See Chapter 6 Using the Setup Utility program on p...

Page 53: ...procedures on page 193 3 Go to Undetermined problems on page 62 006 199 XXX Diskette interface test failed cause unknown 1 Go to Undetermined problems on page 62 2 Flash the system and re test 3 Replace component under function test 006 25X XXX Diskette interface Error 1 Diskette drive cable 2 Diskette drive 3 System board 011 000 XXX Serial port Interface Test Passed No action 011 001 XXX Serial ...

Page 54: ...res on page 193 3 Replace component under function test 011 2XX XXX Serial port signal failure 1 External serial device 2 System board 014 000 XXX Parallel port Interface Test Passed No action 014 001 XXX Parallel port Presence 1 Remove external parallel device if present 2 Run the Setup Utility program enable port 3 System board 014 002 XXX 014 003 XXX Parallel port Timeout Parity error System bo...

Page 55: ...ce Test Passed No action 015 001 XXX USB port Presence 1 Remove USB device s and re test 2 System board 015 002 XXX USB port Timeout 1 Remove USB device s and re test 2 System board 015 015 XXX USB port External Loopback failure 1 Remove USB device s and re test 2 System board 015 027 XXX USB port Configuration Setup error 1 Flash the system See Flash update procedures on page 193 2 System board 0...

Page 56: ... PCI Card Test Passed No action 018 0XX XXX PCI Card Failure 1 Riser card if installed 2 System board 018 195 XXX PCI Card Test aborted by user 1 PCI card 2 Information only Restart the test if necessary 018 196 XXX PCI Card test halt error threshold exceeded 1 Press F3 to review the log file 2 Restart the test to reset the log file 018 197 XXX PCI Card test warning 1 Make sure the component that ...

Page 57: ...X PCI test aborted 1 If a component is called out make sure it is connected and or enabled See Chapter 6 Using the Setup Utility program on page 37 2 Flash the system and re test See Flash update procedures on page 193 3 Go to Undetermined problems on page 62 020 199 XXX PCI test failed cause unknown 1 Go to Undetermined problems on page 62 2 Flash the system and re test See Flash update procedure...

Page 58: ...he Setup Utility program on page 37 2 Flash the system and re test See Flash update procedures on page 193 3 Go to Undetermined problems on page 62 025 199 XXX IDE interface test failed cause unknown 1 Go to Undetermined problems on page 62 2 Flash the system and re test See Flash update procedures on page 193 3 Replace component under function test 030 000 XXX SCSI interface Test Passed No action...

Page 59: ... XXX RAID interface Failure 1 RAID signal cable 2 RAID device 3 RAID adapter card if installed 4 System board 035 195 XXX RAID interface Test aborted by user Information only Restart the test if necessary 035 196 XXX RAID interface test halt error threshold exceeded 1 Press F3 to review the log file 2 Restart the test to reset the log file 035 197 XXX RAID interface test warning 1 Make sure the co...

Page 60: ... warning statement 4 Replace the component under test 071 198 XXX Audio port test aborted 1 If a component is called out make sure it is connected and or enabled See Chapter 6 Using the Setup Utility program on page 37 2 Flash the system and re test See Flash update procedures on page 193 3 Go to Undetermined problems on page 62 071 199 XXX Audio port test failed cause unknown 1 See Undetermined p...

Page 61: ...ouse 2 System board 086 032 XXX Mouse Port interface Device controller failure 1 Mouse 2 System board 086 035 XXX Mouse Port interface Reset 1 Mouse 2 System board 086 040 XXX Mouse Port interface IRQ failure 1 Run the Setup Utility program 2 Mouse 3 System board 086 195 XXX Mouse Port interface Test aborted by user Information only Restart the test if necessary 086 196 XXX Mouse Port interface te...

Page 62: ...ined problems on page 62 089 199 XXX Microprocessor test failed cause unknown 1 See Undetermined problems on page 62 2 Flash the system and re test See Flash update procedures on page 193 3 Replace component under function test 170 000 XXX Voltage Sensor s Test Passed No action 170 0XX XXX Voltage Sensor s failure 1 Flash system 2 System board 170 195 XXX Voltage Sensor s Test aborted by user Info...

Page 63: ...t is called out is connected and or enabled See Chapter 6 Using the Setup Utility program on page 37 2 Re run test 3 Replace the component that is called out in warning statement 4 Replace the component under test 175 198 XXX Thermal Sensor s test aborted 1 If a component is called out make sure it is connected and or enabled 2 Flash the system and re test See Flash update procedures on page 193 3...

Page 64: ...or 1 Hard Disk Drive Cable 2 Check power supply voltages 3 Reseat the hard disk drive cable 4 Hard Disk drive IDE 5 System board 217 28X XXX 217 29X XXX Hard Disk Drive SCSI error 1 Hard Disk Drive Cable 2 Check power supply voltages 3 Reseat the hard disk drive cable 4 Hard Disk drive SCSI 5 SCSI adapter card 6 System board 220 000 XXX Hi Capacity Cartridge Drive Test Passed No action 220 XXX XXX...

Page 65: ...or Perform the following actions in order 1 Make sure the memory module s are properly seated in the connector s 2 Replace the memory module s 3 Replace the system board POST error codes Each time you power on the system it performs a series of tests that check the operation of the system and some options This series of tests is called the Power On Self Test or POST POST does the following operati...

Page 66: ... Power off and remove all but the reader that you set up within your main operating system If more than one external fingerprint reader are connected to a computer this error message will be displayed to inform you to remove all of the fingerprint keyboards except the one compatible with the fingerprint application on your computer 1962 No operating system found Press any key to repeat boot sequen...

Page 67: ...cursor 1 System Board 2 Primary Hard Disk Drive 3 Hard Disk Drive Cable Incorrect memory size during POST 1 Run the Memory tests 2 Memory Module 3 System Board Insert a Diskette icon appears with a known good diagnostics diskette in the first 3 5 inch diskette drive 1 System Board 2 Diskette Drive Cable 3 Network Adapter Intensity or color varies from left to right of characters and color bars 1 D...

Page 68: ...4 System Board Serial or parallel port device failure adapter port 1 External Device Self Test OK 2 External Device 3 Cable 4 Alternate Adapter 5 System Board Some or all keys on the keyboard do not work 1 Keyboard 2 Keyboard Cable 3 System Board Undetermined problems This section provides instructions on how to find out the failing devices or adapters 1 Power off the computer 2 Remove or disconne...

Page 69: ... for major FRUs Not all FRUs are documented Important Before you replace any FRU read Chapter 2 Safety information on page 3 These precautions and guidelines will help you work safely FRU replacements are to be done by trained service technicians only Copyright Lenovo 2010 2011 63 ...

Page 70: ...trol and indicator locations 1 Integrated camera with MIC microphone available in some models 8 Wireless activity indicator 2 Integrated camera on off button 9 Menu Enter 3 Liquid crystal display LCD panel 10 Brightness control Right 4 Power switch 11 Image setup control Left 5 Power indicator 12 Monitor mode control Exit 6 Hard disk drive activity indictor 13 Microphone mute on control 7 Bluetoot...

Page 71: ...ontrol on the front of your computer to switch your computer between computer mode and monitor mode The following table explains the functions of each control when your computer works in computer mode or monitor mode Icon Control Description Menu Open the main On Screen Display OSD menu Enter Confirm a selection Brightness control Adjust overall monitor brightness Right Move to the right Image set...

Page 72: ...your computer Figure 2 Rear connector and part locations 1 Card reader available in some models 8 PS 2 keyboard connector available in some models 2 USB connectors 2 9 Power cord connector 3 Slim optical drive 10 Ethernet connector 4 Headphone connector 11 USB connectors 4 5 Microphone connector 12 DisplayPort out connector 6 Serial port available in some models 13 VGA IN connector 7 PS 2 mouse co...

Page 73: ...ustration shows the locations of the FRUs 32 31 33 34 35 Figure 3 FRU locations 1 Frame stand 19 Power cord connector bracket 2 Computer cover 20 Front panel control board 3 Fan duct 21 Power switch module Chapter 8 Replacing FRUs 67 ...

Page 74: ...ory 27 LCD panel 10 WI FI card 28 Right I O assembly 11 Battery 29 Card reader 12 Microprocessor fan 30 Power supply 13 System board 31 Optical drive 14 Internal speaker 32 Hard disk drive 15 Rear I O assembly cover 33 Integrated camera with microphone 16 Bluetooth module 34 Ambient light sensor 17 Frame foot 35 Handle bar 18 System fan 68 ThinkCentre Hardware Maintenance Manual ...

Page 75: ...rive power connector 6 Ambient light sensor cable connector 20 PS 2 keyboard and mouse connector 7 Bluetooth module cable connector 21 SATA connector 8 Wireless keyboard and mouse connector 22 SATA connector 9 Clear CMOS Complementary Metal Oxide Semiconductor Recovery jumper 23 Optical drive power connector 10 Battery 24 Low voltage differential signaling LVDS cable connector 11 Internal speaker ...

Page 76: ...n the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and the cover is facing up 3 Loose the four screws 1 that secure the frame stand Note Do not try to remove the four screws because they are integrated parts of the frame stand Figure 5 Removing the frame stand 4 Lift the frame stand off the computer and put it in a safe place 5 To...

Page 77: ...the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean towel or cloth on the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and the cover is facing up 3 Remove any locking device that secur...

Page 78: ...l attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Remove the computer cover See Removing the computer cover on page 71 3 Locate the hard disk drive in the computer See FRU locations on page 67 4 Remove the two screws that secure the hard disk drive Then disconnect the hard disk drive cable and ...

Page 79: ...s align with those in the bracket 7 Install the four screws that secure the hard disk drive to the hard disk drive bracket 8 Connect the hard disk drive cable 9 Slide the new hard disk drive with the bracket into the hard disk drive bay Figure 9 Installing the hard disk drive 10 Install the two screws to secure the hard disk drive bracket Chapter 8 Replacing FRUs 73 ...

Page 80: ...llowing 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean towel or cloth on the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and the cover is facing up 3 Remo...

Page 81: ... secure the optical drive 9 Go to Completing the parts replacement on page 111 Replacing the right I O assemblies Attention Do not open your computer or attempt any repair before reading and understanding the Important safety information in the ThinkCentre Safety and Warranty Guide that came with your computer To obtain a copy of the ThinkCentre Safety and Warranty Guide go to http www lenovo com ...

Page 82: ...blies See FRU locations on page 67 Note The right I O assemblies are located on both sides of the optical drive bay See Figure 13 Removing the right I O assemblies on page 76 5 Disconnect all the right I O assembly cables 6 Remove the four screws 1 and 2 that secure the right I O assemblies and then remove the right I O assemblies from the computer Figure 13 Removing the right I O assemblies 7 To ...

Page 83: ...er Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean towel or cloth on the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and the cover is facing up 3 Remove the computer cover See Removing the computer cover on page 71 4 Locate the card reader i...

Page 84: ...to the computer 2 Place a soft clean towel or cloth on the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and the cover is facing up 3 Remove the computer cover See Removing the computer cover on page 71 4 Remove the hard disk drive See Replacing the hard disk drive on page 72 5 Remove the optical drive See Replacing the optical dri...

Page 85: ... the power supply do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean towel or cloth on the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and th...

Page 86: ...he power cord connector bracket with those in the computer main bracket and install the two screws to secure the power cord connector bracket 15 Connect the new power supply cables to the power supply connectors on the system board See System board parts and connectors on page 69 16 Reinstall the PS2 COM Port See Replacing the PS2 COM Port on page 90 17 Reinstall the optical drive See Replacing th...

Page 87: ...ee Removing the computer cover on page 71 4 Remove the hard disk drive See Replacing the hard disk drive on page 72 5 Remove the three screws 1 and 3 that secure the wall mount to the computer main bracket Figure 16 Removing the computer wall mount 6 Note the routing of the thermal sensor cable Then disconnect the thermal sensor cable 2 from the system board See System board parts and connectors o...

Page 88: ...g 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean towel or cloth on the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and the cover is facing up 3 Remove the...

Page 89: ...tem fan on the main bracket and align the screw holes in the new system fan with those in the main bracket 10 Install the three screws that secure the system fan to the main bracket 11 Reinstall the wall mount See Removing or reinstalling the wall mount on page 80 12 Reinstall the hard disk drive See Replacing the hard disk drive on page 72 13 Go to Completing the parts replacement on page 111 Cha...

Page 90: ...all cables that are connected to the computer 2 Place a soft clean towel or cloth on the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and the cover is facing up 3 Remove the computer cover See Removing the computer cover on page 71 4 Remove the hard disk drive See Replacing the hard disk drive on page 72 5 Remove the wall mount Se...

Page 91: ...omputer or attempt any repair before reading and understanding the Important safety information in the ThinkCentre Safety and Warranty Guide that came with your computer To obtain a copy of the ThinkCentre Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the heat sink CAUTION The heat sink might be very hot Turn off the computer and w...

Page 92: ...See FRU locations on page 67 7 Remove the fan duct by pressing the two tabs 1 inward and then pivoting the fan duct upward Figure 20 Removing the fan duct 8 Follow the sequence on the heat sink to loose the four screws that secure the heat sink to the system board Note Carefully loose the four screws from the system board to avoid any possible damage to the system board The four screws cannot be r...

Page 93: ...n in Figure 21 Removing the heat sink on page 87 12 To reinstall the fan duct position the fan duct on the heat sink and then press the fan duct downward until the two tabs on the fan duct are secured into place 13 Go to Completing the parts replacement on page 111 Replacing the microprocessor Attention Do not open your computer or attempt any repair before reading and understanding the Important ...

Page 94: ...Removing the computer cover on page 71 4 Remove the hard disk drive See Replacing the hard disk drive on page 72 5 Remove the wall mount See Removing or reinstalling the wall mount on page 80 6 Remove the heat sink to gain access to the microprocessor See Replacing the heat sink on page 85 7 Press the small handle 1 and open the retainer 2 to access the microprocessor 3 8 Lift the microprocessor s...

Page 95: ...ure 22 Removing the microprocessor 9 Make sure that the small handle is in the raised position and the microprocessor retainer is fully open 10 Hold the new microprocessor and align the notches 2 on it with the alignment keys in the microprocessor socket or align the small triangle 1 on one corner of the new microprocessor with the corresponding beveled corner of the microprocessor socket Chapter ...

Page 96: ...before reading and understanding the Important safety information in the ThinkCentre Safety and Warranty Guide that came with your computer To obtain a copy of the ThinkCentre Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the PS2 COM Port To replace the PS2 COM Port do the following 1 Remove all media from the drives and turn off a...

Page 97: ...on page 111 Installing or replacing a memory module Attention Do not open your computer or attempt any repair before reading and understanding the Important safety information in the ThinkCentre Safety and Warranty Guide that came with your computer To obtain a copy of the ThinkCentre Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to install o...

Page 98: ... you are replacing a memory module open the retaining clips and remove the old memory module that is currently installed Figure 25 Removing the memory module If you are installing a memory module open the retaining clips of the memory slot into which you want to install the memory module 7 Insert the notched end 1 of the new memory module into the slot Press the memory module firmly and pivot the ...

Page 99: ...rmation including passwords are lost An error message will be displayed when you turn on the computer Refer to the Lithium battery notice in the ThinkCentre Safety and Warranty Guide for information about replacing and disposing of the battery To replace the battery do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cord...

Page 100: ...t This section provides instructions on how to replace the WI FI card Note The WI FI card is available only in some models To replace the WI FI card do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean towel or c...

Page 101: ...e Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the Bluetooth module Note The Bluetooth module is available only in some models To replace the Bluetooth module do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect...

Page 102: ...on how to replace the multi touch board Note The multi touch board is available only in some models To replace the multi touch board do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean towel or cloth on the desk...

Page 103: ... came with your computer To obtain a copy of the ThinkCentre Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the ambient light sensor Note The ambient light sensor is available only in some models To replace the ambient light sensor do the following 1 Remove all media from the drives and turn off all attached devices and the computer...

Page 104: ...r screws 1 and 2 that secure the handle bar Figure 32 Removing the handle bar 6 Carefully remove the two screws 1 that secure the ambient light sensor and then lift the ambient light sensor out of the computer Figure 33 Removing the ambient light sensor 98 ThinkCentre Hardware Maintenance Manual ...

Page 105: ...nd Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the internal speakers To replace the internal speakers do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean...

Page 106: ...ranty Guide go to http www lenovo com support This section provides instructions on how to replace the integrated camera with microphone Note The integrated camera with microphone is available only in some models To replace the integrated camera with microphone do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords fro...

Page 107: ...ble from the system board See System board parts and connectors on page 69 7 Remove the two screws 1 that secure the integrated camera with microphone to the front bezel and then remove the integrated camera with microphone from the computer Figure 36 Removing the integrated camera with microphone Chapter 8 Replacing FRUs 101 ...

Page 108: ...ortant safety information in the ThinkCentre Safety and Warranty Guide that came with your computer To obtain a copy of the ThinkCentre Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the rear I O assembly To replace the rear I O assembly do the following 1 Remove all media from the drives and turn off all attached devices and the co...

Page 109: ...y of the ThinkCentre Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the power switch module To replace the power switch module do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to ...

Page 110: ...main bracket off the front bezel 8 Remove the screw that secures the power switch module to the front bezel 9 Disconnect the power switch module cable from the system board and then lift the power switch module off the front bezel 10 Position the new power switch module on the front bezel and align the screw hole in the new power switch module with that in the front bezel 11 Connect the power swit...

Page 111: ... all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconnect all cables that are connected to the computer 2 Place a soft clean towel or cloth on the desk or surface Hold the sides of your computer and gently lay it down so that the screen is against the surface and the cover is facing up 3 Remove the computer ...

Page 112: ... in the ThinkCentre Safety and Warranty Guide that came with your computer To obtain a copy of the ThinkCentre Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the system board To replace the power system board do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all po...

Page 113: ...on page 69 16 Remove the nine screws that secure the system board to the main bracket Carefully lift the system board out of the chassis 17 Place the new system board into the chassis and align the screw holes with those in the chassis 18 Install the nine screws that secure the system board to the main bracket 19 Reinstall the rear I O assembly See Replacing the rear I O assembly on page 102 20 Re...

Page 114: ...securing the microprocessor retainer and open the retainer to access the microprocessor 2 Grasp the microprocessor on the sides and lift it straight up and out of the socket Do not touch the contacts on the microprocessor socket 3 Note the orientation of the socket cover Align the notches 1 of the microprocessor socket cover with the alignment keys 2 of the microprocessor socket 4 Install one side...

Page 115: ...rranty Guide that came with your computer To obtain a copy of the ThinkCentre Safety and Warranty Guide go to http www lenovo com support This section provides instructions on how to replace the LCD panel To replace the LCD panel do the following 1 Remove all media from the drives and turn off all attached devices and the computer Then disconnect all power cords from electrical outlets and disconn...

Page 116: ... computer Note Do not break the tape or remove the tape from the computer You will need the tape when installing the new LCD panel 9 Place the new LCD panel into the front bezel and then stick the three pieces of black tape back to the LCD panel 10 Position the computer main bracket over the LCD panel Make sure the screw holes in the computer main bracket align with those in the front bezel 11 Rei...

Page 117: ...lowing 1 Make sure that all components have been reassembled correctly and that no tools or loose screws are left inside your computer See FRU locations on page 67 for the locations of various components in your computer 2 Make sure that the cables are routed correctly before reinstalling the computer cover Keep cables clear of the hinges and sides of the computer chassis to avoid interference wit...

Page 118: ...k 6 Reconnect the external cables and power cord to the computer 7 Depending on the parts you installed or replaced you might need to confirm the updated information in the Setup Utility program Refer to Chapter 6 Using the Setup Utility program on page 37 Note In most areas of the world Lenovo requires the return of the defective Customer Replaceable Unit CRU Information about this will come with...

Page 119: ...mer replaceable unit CRU is identified as 1 2 or N in the CRU column N means that the part is not a CRU 1 means that the part is a Self service CRU and 2 means that the part is an Optional service CRU Overall MT 7570 7577 7578 7580 7583 7584 7589 7594 7595 7597 and 7598 The Fru list below is for MTs Standard MTs 7577 7580 7583 7584 7589 7597 and 7598 Special Bid MTs 7570 7578 7594 and 7595 Copyrig...

Page 120: ...nel control board 3 Fan duct 21 Power switch module 4 Wall mount 22 Internal speaker 5 Thermal sensor 23 PS2 COM Port 6 Multi touch board 24 Computer main bracket 7 Heat sink 25 Right I O assembly 8 Microprocessor 26 Inverter 9 Memory 27 LCD panel 114 ThinkCentre Hardware Maintenance Manual ...

Page 121: ...models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9550 2 2 Computer cover rear cover sub assembly MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9555 2 3 Fan duct microprocessor fan duct MT 7577 a...

Page 122: ...7594 and 7595_SB 03T9572 1 7 Heat sink L2 Intel 73W thermal cooler kit MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9530 2 8 Microprocessor Clarkdale Pentium G6950 2 80G 1066MHz Dual core 3M 73W LGA 1156 Gfx core speed 533MHz MT 7577 MT 7580 MT 7583 A5J A6J B1J B2J B8J B9J MT 75...

Page 123: ...594 and 7595_SB 89Y9195 N 8 Microprocessor Clarkdale Core i5 650 3 20G 1333MHz 4T Dual core 4M 73W Turbo LGA 1156 Gfx core speed 733MHz MT 7577 B7B D1B B3A B3T B4A B4T B6A B6T E2J E3J D2V D3V G1J G2J MT 7580 A1G MT 7583 A2J A1J B5J MT 7584 B2S B2D B2Y B3G B5J B7J MT 7589 B1V B4G MT 7597 CTO A9B C6S C6D C6Y A0J B1J B6J B7J A4P D1P D1B D1J D2P D2B D2J D5A D5T D6T D0A D0T E1A E1T A8B A6G D1S D1A D1Q ...

Page 124: ... 1156 Gfx core speed 733MHz MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 89Y9196 N 8 Microprocessor Clarkdale Core i3 560 3 30G 1333MHz Dual core 4M 73W Gfx core speed 733MHz MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T7035 N 9 Memory module 1GB PC3 8500 1066MHz DDR3 SoDIMM MT 7577 MT 7580 MT 7583 MT 7584...

Page 125: ...4J E5J D2V D3V D4V D5V D6V G1J G2J G3J G4J MT 7580 A0G A1G MT 7583 A2J A3J A4J A5J A1J B1J B3J B4J B5J B6J B7J B8J MT 7584 BIS BID BIY B2S B2D B2Y B3G B4G B7J MT 7589 A1S A1D A1Y A2S A2D A2Y A3D A3Y A3S B1V B2V B3G B4G MT 7597 CTO A7B A9B C7B C8B C9B C2S C2D C2Y C3D C3Y C4S C4D C4Y C5S C5D C5Y C6S C6D C6Y A0J B1J B2J B3J B4J B5J B6J B7J B8J B9J B0J C1J A1P A2P A3P A4P D1P D1B D1J D2P D2B D2J D3T D...

Page 126: ... Puma Peak WiFi card antenna kit MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 89Y6220 2 10 WI FI card Intel Puma Peak WiFi card MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 60Y3233 2 120 ThinkCentre Hardware Maintenance Manual ...

Page 127: ...fan 4 Pin PWM blower microprocessor fan MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 45K6403 2 13 System board H57 Planar in barebone MT 7577 B7B B8B B9B D1B B1A B1T B2A B2T B3A B3T B4A B4T B5A B5T B6A B6T D7A D8G D8T D9A D9T E1G E1A E1T E2J E3J E4J E5J D2V D3V D4V D5V D6V G1J G2J ...

Page 128: ...1P A2P A3P A4P D1P D1B D1J D2P D2B D2J D3T D4A D4T D5A D5T D6T D7T D8T D9T D0A D0T E1A E1T E2A E2T E3T E4A E4T A8B C3S A5G A6G D1S D1A D1Q E5Q E6Q D2S D2A D2Q D3A D6A D7A D8A D9A E7S E7D E7Y E8S E8D E8Y G1J G2J G3J G4J G5J G6J G7J G8J G9J H1J H2J H3J MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 03T6438 N 14 Internal speaker speaker module MT 7577 all models MT 7580 all models MT 7583 all ...

Page 129: ...7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9551 2 18 System fan 4 pin PWM blower system fan MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9531 N 19 Power cord connector bracket plugs MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all mod...

Page 130: ...MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9539 2 22 Internal speaker MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9562 1 23 PS2 and COM module with mechanical parts MT 7577 all models MT 7580 all models MT 7583 a...

Page 131: ...584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9535 2 26 Inverter Inverter PCBA MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9573 1 27 LCD panel Samsung 19 CCFL panel MT 7577 all models MT 7580 all models MT 7583 all mode...

Page 132: ...l models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9533 N 27 LCD panel LG LCD touch assembly MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9534 2 28 Right I O assembly with cable kit MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all...

Page 133: ...3T D4A D4T D5A D5T D6T D7T D8T D9T D0A D0T E1A E1T E2A E2T E3T E4A E4T A8B C3S A5G A6G D1S D1A D1Q E5Q E6Q D2S D2A D2Q D3A D6A D7A D8A D9A E7S E7D E7Y E8S E8D E8Y G1J G2J G3J G4J G5J G6J G7J G8J G9J H1J H2J H3J MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 89Y1686 2 31 Optical drive SATA Slim ODD Rambo MT 7577 B7B B8B B9B D1B B1A B1T B2A B2T B3A B3T B4A B4T B5A B5T B6A B6T D7A D8G D8T D9A ...

Page 134: ... MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 40Y9035 1 32 Hard disk drive SATA 160GB 7200RPM 3Gb 8M MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 53Y6837 1 32 Hard disk drive SATA 250GB 7200RPM 3Gb 8M MT 7577 G3J G4J MT 7580 MT 7583 A3J A4J A5J A6J B1J B2J B3J B4J B6J B7J B8J B9J MT 7584 B6J MT 7589 MT 7597 CTO B2J B3J B4J B5J B8J B9J B0J C1J D3T D...

Page 135: ...5S C5D C5Y C6S C6D C6Y A0J B1J B6J B7J A1P A2P A3P A4P D1P D1B D1J D2P D2B D2J D4A D4T D5A D5T D6T D9T D0A D0T E1A E1T E2A E2T C3S A5G D1S D1A D1Q E5Q E6Q D2S D2A D2Q D6A D9A G1J G2J G3J G4J MT 7598 B1G B2G MT 7570 7578 7594 and 7595_SB 45K0409 1 32 Hard disk drive SATA 320GB 7200 RPM 3Gb 8M MT 7577 B1A B1T B2A B2T B3A B3T B4A B4T B5A B5T D7A D8G D8T D9A D9T E2J E3J D2V D4V D6V G1J G2J MT 7580 A0G...

Page 136: ...B B8B B9B D1B B6A B6T E1G E1A E1T E4J E5J D3V D5V MT 7580 A1G MT 7583 MT 7584 B3G MT 7589 B3G B4G MT 7597 CTO A9B C7B C8B C9B D7T A8B A6G D7A E7S E7D E7Y E8S E8D E8Y MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 41X5582 1 32 Hard disk drive SATA 1TB 7200RPM 3Gb 32M MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 45K0412 1 32 Hard disk drive 2 5 inch 150G 1...

Page 137: ...models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9541 1 34 Ambient light sensor light sensor board with cable kit MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 89Y6232 2 Mechanical FRUs The FRUs listed in the following tables are not illustrated FRUs FRU CRU Mechanical cap...

Page 138: ...models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 60Y3241 2 Intrusion switch with cable kit MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 89Y6223 2 FRU 1 8 SSD to 2 5 HDD conversion kit MT 7577 all models MT 7580 all models MT 7583 all mod...

Page 139: ...l models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9553 2 FRU non touch without camera bezel kit with front panel control board MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9554 2 FRU LVDS cable MT 7577 all models MT 7580 all model...

Page 140: ...ll models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9559 N FRU ODD retainer MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9560 N FRU ODD cable assembly MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7...

Page 141: ...all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9575 2 FRU card reader bezel MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9576 2 Wall mount cover sub assembly MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 al...

Page 142: ... MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9545 2 Mechanical kit non touch without camera MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT 7589 all models MT 7597 all models MT 7598 all models MT 7570 7578 7594 and 7595_SB 03T9546 2 Lift stand MT 7577 all models MT 7580 all models MT 7583 all models MT 7584 all models MT...

Page 143: ... B5A B6A D7A D8G D9A E1G E1A MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 MT 7597 CTO D4A D5A D0A E1A E2A E4A A5G A6G D1A D1Q E5Q E6Q D2A D2Q D3A D6A D7A D8A D9A MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5289 1 Arabic MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5290 1 Arabic F...

Page 144: ...MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5293 1 Brazilian Portuguese MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO A1P A2P A3P A4P D1P D2P MT 7598 MT 7570 7578 7594 and 7595_SB 41A5294 1 Bulgarian MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 ...

Page 145: ...MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5297 1 Danish MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5298 1 Dutch MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G...

Page 146: ...MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41A5301 1 French Canadian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41A5302 1 German MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5303 1 140 ThinkCentre Hardw...

Page 147: ... B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5305 1 Hebrew MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5306 1 Hungarian MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT...

Page 148: ...2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5309 1 Japanese MT 7577 E2J E3J E4J E5J G1J G2J G3J G4J MT 7580 MT 7583 A2J A3J A4J A5J A1J A6J B1J B2J B3J B4J B5J B6J B7J B8J B9J MT 7584 B5J B6J B7J MT 7589 MT 7597 CTO A0J B1J B2J B3J B4J B5J B6J B7J B8J B9J B0J C1J D1J D2J G1J G2J G3J G4J G5J G6J G7J G8J G9J H1J H2J H3J MT 7598 MT 7570 7578 7594 and 7595_SB 41A5310 1 Korean MT 7577 MT 7580 MT 7583 M...

Page 149: ...ian MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5313 1 Polish MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5314 1 Portuguese MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3...

Page 150: ...B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5316 1 Russian Cyrillic MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5318 1 Serbian Cyrillic MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT...

Page 151: ...MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5321 1 Swedish Finnish MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5322 1 Swiss French German MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G ...

Page 152: ... MT 7584 MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5325 1 Turkish MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5326 1 UK English MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G ...

Page 153: ...4 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41A5329 1 Arabic New MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 45J4880 1 Lithuanian MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G ...

Page 154: ...S English Chinese Simplified MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8001 1 Arabic MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8002 1 Arabic French MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8003 1 148 ThinkCentre Hardware Maintenance Manual ...

Page 155: ...gium English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8005 1 Brazilian Portuguese MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8006 1 Bulgarian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8007 1 Chapter 9 FRU lists 149 ...

Page 156: ...ch ABB MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8009 1 Danish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8010 1 Dutch MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8011 1 150 ThinkCentre Hardware Maintenance Manual ...

Page 157: ...nch Canadian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8013 1 French Canadian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8014 1 German MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8015 1 Chapter 9 FRU lists 151 ...

Page 158: ...S MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8017 1 Hebrew MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8018 1 Hungarian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8019 1 152 ThinkCentre Hardware Maintenance Manual ...

Page 159: ...020 1 Italy MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8021 1 Japanese MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8022 1 Korean MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8023 1 Chapter 9 FRU lists 153 ...

Page 160: ...ian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8025 1 Polish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8026 1 Portuguese MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8027 1 154 ThinkCentre Hardware Maintenance Manual ...

Page 161: ...nian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8039 1 Russian Cyrillic MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8028 1 Serbian Cyrillic MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8040 1 Chapter 9 FRU lists 155 ...

Page 162: ...MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8030 1 Swedish Finnish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8031 1 Swiss French German MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8032 1 156 ThinkCentre Hardware Maintenance Manual ...

Page 163: ...3 1 Turkish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8041 1 Turkish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8034 1 UK English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8035 1 Chapter 9 FRU lists 157 ...

Page 164: ...584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03X8037 1 Ultra slim Wireless FRU CRU Wireless US English Chinese Simplified MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4740 1 Wireless Arabic MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4741 1 158 ThinkCentre Hardware Maintenance Manual ...

Page 165: ...T 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4743 1 Wireless Belgium English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4744 1 Wireless Brazilian Portuguese MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4745 1 Chapter 9 FRU lists 159 ...

Page 166: ...77 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4747 1 Wireless Czech ABB MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4748 1 Wireless Danish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4749 1 160 ThinkCentre Hardware Maintenance Manual ...

Page 167: ...7 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4751 1 Wireless French Canadian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4752 1 Wireless French Canadian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4753 1 Chapter 9 FRU lists 161 ...

Page 168: ...MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4755 1 Wireless Greek US MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4756 1 Wireless Hebrew MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4757 1 162 ThinkCentre Hardware Maintenance Manual ...

Page 169: ...land MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4759 1 Wireless Italy MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4760 1 Wireless Japanese MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4761 1 Chapter 9 FRU lists 163 ...

Page 170: ...7 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4763 1 Wireless Norwegian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4764 1 Wireless Polish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4765 1 164 ThinkCentre Hardware Maintenance Manual ...

Page 171: ... Cyrillic MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4767 1 Wireless Slovak MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4768 1 Wireless Spanish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4769 1 Chapter 9 FRU lists 165 ...

Page 172: ...an MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4771 1 Wireless Thailand MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4772 1 Wireless Turkish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4773 1 166 ThinkCentre Hardware Maintenance Manual ...

Page 173: ...98 MT 7570 7578 7594 and 7595_SB 57Y4774 1 Wireless US European MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4775 1 Wireless Slovenian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 57Y4776 1 Chapter 9 FRU lists 167 ...

Page 174: ...1S A1D A1Y A2S A2D A2Y A3D A3Y A3S B1V B2V B3G B4G MT 7597 CTO A7B A9B C7B C8B C9B C2S C2D C2Y C3D C3Y C4S C4D C4Y C5S C5D C5Y C6S C6D C6Y A0J B1J B2J B3J B4J B5J B6J B7J B8J B9J B0J C1J A1P A2P A3P A4P D1P D1B D1J D2P D2B D2J D3T D4A D4T D5A D5T D6T D7T D8T D9T D0A D0T E1A E1T E2A E2T E3T E4A E4T A8B C3S A5G A6G D1S D1A D1Q E5Q E6Q D2S D2A D2Q D3A D6A D7A D8A D9A E7S E7D E7Y E8S E8D E8Y G1J G2J G...

Page 175: ... B3T B4A B4T B5A B5T B6A B6T D7A D8G D8T D9A D9T E1G E1A E1T E2J E3J E4J E5J D2V D3V D4V D5V D6V G1J G2J G3J G4J MT 7580 A0G A1G MT 7583 A2J A3J A4J A5J A1J A6J B1J B2J B3J B4J B5J B6J B7J B8J B9J MT 7584 BIS BID BIY B2S B2D B2Y B3G B4G B5J B6J B7J MT 7589 A1S A1D A1Y A2S A2D A2Y A3D A3Y A3S B1V B2V B3G B4G MT 7597 CTO A7B A9B C7B C8B C9B C2S C2D C2Y C3D C3Y C4S C4D C4Y C5S C5D C5Y C6S C6D C6Y A0J...

Page 176: ...41R3184 1 Line cord China MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3256 1 Line cord Japan MT 7577 E2J E3J E4J E5J G1J G2J G3J G4J MT 7580 MT 7583 A2J A3J A4J A5J A1J A6J B1J B2J B3J B4J B5J B6J B7J B8J B9J MT 7584 B5J B6J B7J MT 7589 MT 7597 CTO A0J B1J B2J B3J B4J B5J B6J B7J B8J B9J B0J C1J D1J D2J G1J G2J G3J G4J G5J G6J G7J G8J G9J H1J H2J H3...

Page 177: ... 7595_SB 41R3176 1 Line cord ANZ MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3196 1 Line cord Korea MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3260 1 Line cord Taiwan MT 7577 D2V D3V D4V D5V D6V MT 7580 MT 7583 MT 7584 MT 7589 B1V B2V MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3278 1 Chapte...

Page 178: ...T 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41R3212 1 Line cord Switzerland MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41R3228 1 Line cord Israel MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3...

Page 179: ...1 Line cord Indonesia Laos Cambodia and Vietnam Austria Belgium Croatia Czechoslovakia Finland France Germany Hungary Netherlands Norway Poland Portugal Romania Spain Sweden MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3208 1 Line cord Hong Kong Singapore Malaysia Brunei UK Ireland MT 7577 B7B B8B B9B D1B D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B...

Page 180: ...85 1 Line cord China MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3257 1 Line cord Japan MT 7577 E2J E3J E4J E5J G1J G2J G3J G4J MT 7580 MT 7583 A2J A3J A4J A5J A1J A6J B1J B2J B3J B4J B5J B6J B7J B8J B9J MT 7584 B5J B6J B7J MT 7589 MT 7597 CTO A0J B1J B2J B3J B4J B5J B6J B7J B8J B9J B0J C1J D1J D2J G1J G2J G3J G4J G5J G6J G7J G8J G9J H1J H2J H3J MT ...

Page 181: ...d 7595_SB 41R3177 1 Line cord ANZ MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3197 1 Line cord Korea MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3261 1 Line cord Taiwan MT 7577 D2V D3V D4V D5V D6V MT 7580 MT 7583 MT 7584 MT 7589 B1V B2V MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3279 1 Chapt...

Page 182: ...MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41R3213 1 Line cord Switzerland MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B3G B4G MT 7597 CTO A5G A6G MT 7598 B1G B2G B3G B4G MT 7570 7578 7594 and 7595_SB 41R3229 1 Line cord Israel MT 7577 D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 B...

Page 183: ... 1 Line cord Indonesia Laos Cambodia and Vietnam Austria Belgium Croatia Czechoslovakia Finland France Germany Hungary Netherlands Norway Poland Portugal Romania Spain Sweden MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 41R3209 1 Line cord Hong Kong Singapore Malaysia Brunei UK Ireland MT 7577 B7B B8B B9B D1B D8G E1G MT 7580 A0G A1G MT 7583 MT 7584 B3G ...

Page 184: ...3T1184 1 Turkish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1189 1 Serbian Latin MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1188 1 English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1190 1 178 ThinkCentre Hardware Maintenance Manual ...

Page 185: ... 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1185 1 India English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1186 1 Windows 7 Home Premium 32 Recovery CD Windows 7 Home Premium 32 FRU CRU Japanese MT 7577 MT 7580 MT 7583 A6J B2J B9J MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1194 1 Chapter 9 FRU lists 179 ...

Page 186: ...ng Kong MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1193 1 Korean MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1195 1 English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1197 1 180 ThinkCentre Hardware Maintenance Manual ...

Page 187: ...apanese MT 7577 E2J E3J E4J E5J G1J G2J G3J G4J MT 7580 MT 7583 A2J A3J A4J A5J A1J B1J B3J B4J B5J B6J B7J B8J MT 7584 B5J B6J B7J MT 7589 MT 7597 CTO A0J B1J B2J B3J B4J B5J B6J B7J B8J B9J B0J C1J D1J D2J G1J G2J G3J G4J G5J G6J G7J G8J G9J H1J H2J H3J MT 7598 MT 7570 7578 7594 and 7595_SB 03T1202 1 Chinese Traditional Taiwan MT 7577 B8B D2V D3V D4V D6V MT 7580 MT 7583 MT 7584 MT 7589 B1V B2V M...

Page 188: ...70 7578 7594 and 7595_SB 03T1201 1 English MT 7577 B1A B2A B3A B4A B5A B6A D7A D8G D9A E1G E1A MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 MT 7597 CTO A5G A6G MT 7598 B1G B2G MT 7570 7578 7594 and 7595_SB 03T1205 1 Spanish MT 7577 D8G E1A MT 7580 A0G A1G MT 7583 MT 7584 B3G B4G MT 7589 MT 7597 CTO A1P A2P A3P A4P D1P D2P MT 7598 B1G B2G MT 7570 7578 7594 and 7595_SB 03T1204 1 182 ThinkCentre H...

Page 189: ...1 India English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1200 1 Windows 7 Professional 64 Recovery CD Windows 7 Professional 64 FRU CRU Hong Kong MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1213 1 Japanese MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T...

Page 190: ...7B B9B MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1208 1 Arabic MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1206 1 Czech MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1209 1 184 ThinkCentre Hardware Maintenance Manual ...

Page 191: ... 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1214 1 Korean MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1216 1 Polish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1217 1 Chapter 9 FRU lists 185 ...

Page 192: ...7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1219 1 Russian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1220 1 Slovakian MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1221 1 186 ThinkCentre Hardware Maintenance Manual ...

Page 193: ...0 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1224 1 Turkish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1225 1 C L EMEA NL FR GR IT EN MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1227 1 Chapter 9 FRU lists 187 ...

Page 194: ...83 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1223 1 Brazilian Portuguese MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1207 1 India English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 B3G B4G MT 7597 CTO MT 7598 B3G B4G MT 7570 7578 7594 and 7595_SB 03T1210 1 188 ThinkCentre Hardware Maintenance Manual ...

Page 195: ...577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 MT 7598 MT 7570 7578 7594 and 7595_SB 03T0588 1 Windows 7 Starter 32 Recovery CD Windows 7 Starter 32 FRU CRU Arabic MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1178 1 Turkish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1182 1 Chapter 9 FRU lists 189 ...

Page 196: ...glish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1180 1 Spanish MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1181 1 US English MT 7577 MT 7583 MT 7584 MT 7589 MT 7597 CTO MT 7598 MT 7570 7578 7594 and 7595_SB 03T1183 1 190 ThinkCentre Hardware Maintenance Manual ...

Page 197: ...Windows 7 Ultimate 32 Recovery CD Windows 7 Ultimate 32 FRU CRU English MT 7577 MT 7580 MT 7583 MT 7584 MT 7589 MT 7597 MT 7598 MT 7570 7578 7594 and 7595_SB 03T1228 1 Chapter 9 FRU lists 191 ...

Page 198: ...192 ThinkCentre Hardware Maintenance Manual ...

Page 199: ...red in the nonvolatile memory on the system board After you replace the system board the VPD must be updated To update the VPD see Flash update procedures on page 193 BIOS levels An incorrect level of BIOS can cause false errors and unnecessary FRU replacement Use the following information to determine the current level of BIOS installed in the computer the latest BIOS available for the computer a...

Page 200: ...ithout notice including the contents referenced in the following procedure To update flash the BIOS from your operating system do the following 1 Go to http www lenovo com support 2 Do the following to locate the downloadable files for your machine type a In the Enter a product number field type your machine type and click Go b Click Downloads and drivers c Select BIOS from the Refine results drop...

Page 201: ...ion of certain components of the computer such as the system power supply processor hard disk drives and some monitors Automatic configuration and power interface ACPI BIOS Being an ACPI BIOS system the operating system is allowed to control the power management features of the computer and the setting for Advanced Power Management APM BIOS mode is ignored Not all operating systems support ACPI BI...

Page 202: ...196 ThinkCentre Hardware Maintenance Manual ...

Page 203: ...ublication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo...

Page 204: ...ly unless otherwise authorized by Macrovision Corporation Reverse engineering or disassembly is prohibited European conformance CE mark Trademarks Lenovo the Lenovo logo Rescue and Recovery ThinkCentre and ThinkVantage are trademarks of Lenovo in the United States other countries or both Microsoft and Windows are trademarks of the Microsoft group of companies Intel Intel Core and Pentium are trade...

Page 205: ...cing 100 internal speakers replacing 99 inverter replacing 78 L LCD panel replacing 109 Lenovo ThinkVantage Toolbox 33 Lenovo Welcome 29 M memory module 91 installing replacing 91 microprocessor fan assembly replacing 84 multi touch board replacing 96 N notice television output 198 notices 197 O optical drive replacing 74 P parts replacement completing 111 password Administrator password 38 consid...

Page 206: ... 38 Set Power On Password 38 settings changing 37 viewing 37 Setup Utility program 37 Setup Utility program exiting 40 Setup Utility program starting 37 starting the Setup Utility program 37 startup device 39 sequence changing 40 temporary selecting 39 system board replacing 106 system fan replacing 82 T television output notice 198 temporary startup device 39 the BIOS updating flashing 193 194 tr...

Page 207: ......

Page 208: ...Part Number 0A22568 Printed in USA 1P P N 0A22568 0A22568 ...

Reviews: