Diagnostic Error Code
FRU/Action
080-197-XXX
Game Port interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
080-198-XXX
Game Port interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37
2. Flash the system and re-test. See “Flash update
procedures” on page 193.
3. Go to “Undetermined problems” on page 62.
080-199-XXX
Game Port interface test failed, cause
unknown
1. See “Undetermined problems” on page 62.
2. Flash the system and re-test. See “Flash update
procedures” on page 193.
3. Replace component under function test.
086-000-XXX
Mouse Port interface Test Passed
No action
086-001-XXX
Mouse Port interface Presence
1. Mouse
2. System board
086-032-XXX
Mouse Port interface Device controller failure
1. Mouse
2. System board
086-035-XXX
Mouse Port interface Reset
1. Mouse
2. System board
086-040-XXX
Mouse Port interface IRQ failure
1. Run the Setup Utility program.
2. Mouse
3. System board
086-195-XXX
Mouse Port interface Test aborted by user
Information only Restart the test, if necessary.
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
086-197-XXX
Mouse Port interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
086-198-XXX
Mouse Port interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 37.
2. Flash the system and re-test. See “Flash update
procedures” on page 193.
3. Go to “Undetermined problems” on page 62.
Chapter 7
.
Symptom-to-FRU Index
55
Summary of Contents for ThinkCentre M70z
Page 2: ......
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 198: ...192 ThinkCentre Hardware Maintenance Manual ...
Page 202: ...196 ThinkCentre Hardware Maintenance Manual ...
Page 207: ......
Page 208: ...Part Number 0A22568 Printed in USA 1P P N 0A22568 0A22568 ...