2. Turn off the server and peripheral devices, and disconnect the power cord and
all external cables.
3. Slide the server out of the rack.
4. Remove the cover (see “Removing the cover” on page 159).
5. Pull the hard disk drives out of the server slightly to disengage them from the
backplane. See “Removing a hot-swap hard disk drive” on page 211 for details.
6. To obtain more working room, remove the fans and the fan bracket (see
“Removing a hot-swap fan” on page 196 and “Removing the fan bracket” on
page 198).
7. Disconnect the backplane cables.
8. Lift the backplane out of the server by pulling it toward the rear of the server,
then lifting it up.
9. If you are instructed to return the backplane, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
162
ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Hardware Maintenance Manual
Summary of Contents for THINKSERVER 3729
Page 1: ...Hardware Maintenance Manual ThinkServer RD220 Types 3797 3798 3779 and 3729 ...
Page 2: ......
Page 3: ...ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 156: ...148 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 238: ...230 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 265: ......
Page 266: ...Part Number 40M2493 Printed in USA 1P P N 40M2493 ...