5. Remove the DIMM air baffle (see “Removing the DIMM air baffle” on page
177).
Attention:
To avoid breaking the retaining clips or damaging the DIMM
connectors, open and close the clips gently.
6. Open the retaining clip
2
on each end of the DIMM connector.
7. Touch the static-protective package that contains the DIMM to any unpainted
metal surface on the server. Then, remove the DIMM from the package.
8. Turn the DIMM so that the DIMM keys align correctly with the connector.
9. Insert the DIMM into the connector
1
by aligning the edges of the DIMM with
the slots at the ends of the DIMM connector. Firmly press the DIMM straight
down into the connector by applying pressure on both ends of the DIMM
simultaneously. The retaining clips snap into the locked position when the
DIMM is firmly seated in the connector.
Important:
If there is a gap between the DIMM and the retaining clips, the
DIMM has not been correctly inserted; open the retaining clips, remove the
DIMM, and then reinsert it.
10. Install the DIMM air baffle (see “Installing the DIMM air baffle” on page 178).
11. Install PCI riser-card assembly 2, if you removed it (see “Installing a PCI
riser-card assembly” on page 168).
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 227.
If you have other optional devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 227.
Removing a hot-swap power supply
Important:
If the server has two power supplies, and if you remove either of them,
the server will not have redundant power; if the server power load then exceeds
675 W, the server might not start or might not function correctly.
To remove a power supply, complete the following steps.
Chapter 6. Removing and installing FRUs
193
Summary of Contents for THINKSERVER 3729
Page 1: ...Hardware Maintenance Manual ThinkServer RD220 Types 3797 3798 3779 and 3729 ...
Page 2: ......
Page 3: ...ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 8: ...vi ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 156: ...148 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 238: ...230 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 264: ...256 ThinkServer RD220 Types 3729 3779 3797 and 3798 Hardware Maintenance Manual ...
Page 265: ......
Page 266: ...Part Number 40M2493 Printed in USA 1P P N 40M2493 ...