1. Locate the bay for the power supply in the rear of your server. Insert a finger into the hole in the metal
shield that protects the bay, press the tab
1
in the direction as shown, and then pull the shield out of the
chassis. Store the shield in case you later remove the power supply and need the shield to cover the bay.
ID
Figure 64. Removing the protective shield for the power supply bay
2. Touch the static-protective package that contains the new hot-swap redundant power supply to any
unpainted surface on the outside of the server. Then, take the new hot-swap redundant power supply
out of the package.