• If you are using a ThinkServer RAID 700 Adapter, do the following:
1. Use one mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
3
on one end of the
cable to the ports 3-0 on the RAID card. Then, connect the mini-SAS connector
4
on the other end
of the cable to the mini-SAS ports 0-3 on the backplane.
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS signal
cable. Connect the mini-SAS connector
1
on one end of the cable to the ports 7-4 on the RAID
card. Then, connect the mini-SAS connector
2
on the other end of the cable to the mini-SAS ports
4-5 or mini-SAS prots 4-7 on the backplane.
• If you are using a ThinkServer RAID 710 Adapter, do the following:
1. Use the mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
1
to the port 1 on the
RAID card. Then, connect the mini-SAS connector
2
to the mini-SAS ports 0-3 on the backplane.
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS
signal cable. Connect the mini-SAS connector
3
to the port 2 on the RAID card. Then, connect the
mini-SAS connector
4
to the mini-SAS ports 4-5 or mini-SAS ports 4-7 on the backplane.
Refer to the following topics for information about the connector locations:
•
“Hot-swap hard-disk-drive backplane” on page 33
•
•
“System board components” on page 38
System board components
The following illustration shows the component locations on the system board.
38
ThinkServer RD340 User Guide and Hardware Maintenance Manual
Summary of Contents for ThinkServer RD340
Page 18: ...6 ThinkServer RD340 User Guide and Hardware Maintenance Manual ...
Page 84: ...72 ThinkServer RD340 User Guide and Hardware Maintenance Manual ...
Page 188: ...176 ThinkServer RD340 User Guide and Hardware Maintenance Manual ...
Page 198: ...186 ThinkServer RD340 User Guide and Hardware Maintenance Manual ...
Page 214: ...202 ThinkServer RD340 User Guide and Hardware Maintenance Manual ...
Page 215: ......
Page 216: ......