8. Slide the bracket with the drive into the drive bay from the front until it snaps into position and then
completely close the handle.
Figure 125. Installing the bracket with the drive
9. Check the drive status LEDs to ensure that the drive is operating correctly. You might have to restart the
server for the newly installed drive to be recognized. See “Hot-swap-drive activity and status LEDs” on
page 46. If the drive is faulty, reinstall or replace it until it is operating correctly.
10. Save the removed dummy tray in case that you later remove the drive and need a dummy tray to
cover the drive bay.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To configure RAID, go to “Configuring RAID” on page 58.
• To complete the installation, go to “Completing the parts replacement” on page 178.
Replacing the hot-swap-drive backplane
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 63.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Notes:
• The hot-swap-drive backplane is sensitive to ESD. Ensure that you read and understand “Handling
static-sensitive devices” on page 64 first and carefully perform the operation.
• The following procedure is based on the scenario that you want to replace the backplane for up to eight
3.5-inch drives. The procedure is similar if your server is installed with the following types of backplanes:
– Backplane for up to sixteen 2.5-inch drives
– Backplane for up to eight 2.5-inch drives
To replace the backplane, do the following:
146
ThinkServer RD450 User Guide and Hardware Maintenance Manual
Summary of Contents for ThinkServer RD450
Page 14: ...xii ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 62: ...48 ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 76: ...62 ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 196: ...182 ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 206: ...192 ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 218: ...204 ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 224: ...210 ThinkServer RD450 User Guide and Hardware Maintenance Manual ...
Page 225: ......
Page 226: ......