10. Connect the cable of the new ThinkServer RAID Super Capacitor Module to the ThinkServer RAID
Super Capacitor Module connector on the PCI Express card using the extended cable shipped with
the ThinkServer RAID Super Capacitor Module.
Figure 113. Connecting the cable of the ThinkServer RAID Super Capacitor Module to the PCI Express card
11. If you are instructed to return the failing ThinkServer RAID Super Capacitor Module, follow all packaging
instructions and use any packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement procedure, go to “Completing the parts replacement” on page 184.
Installing or replacing a hot-swap hard disk drive
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 75.
This topic provides instructions on how to install or replace a hot-swap hard disk drive.
For a list of the ThinkServer hard disk drive options, go to:
http://lenovoquickpick.com/usa/home/thinkserver/rack-and-tower-server
You can install or replace a hot-swap hard disk drive without turning off the server, which helps you avoid
significant interruption to the operation of the system.
The EMI integrity and cooling of the server are protected by having all drive bays covered or occupied. The
number of the installed hard disk drives in your server varies depending on the server model. The vacant
bays are either covered by an EMI-protective panel or occupied by dummy hard-disk-drive trays. When you
install a hot-swap hard disk drive, save the removed dummy hard-disk-drive tray in the event that you later
remove the hot-swap hard disk drive and need the dummy tray to cover the place.
Attention:
An unoccupied drive bay without any other protection might impact the EMI integrity and cooling
of the server, which might result in overheating or component damage. To maintain the EMI integrity and
cooling of the server, install a new hot-swap hard disk drive as soon as you remove the failing one or
the dummy tray.
146
ThinkServer RD640 User Guide and Hardware Maintenance Manual
Summary of Contents for ThinkServer RD640
Page 14: ...xii ThinkServer RD640 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD640 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD640 User Guide and Hardware Maintenance Manual ...
Page 70: ...56 ThinkServer RD640 User Guide and Hardware Maintenance Manual ...
Page 202: ...188 ThinkServer RD640 User Guide and Hardware Maintenance Manual ...
Page 212: ...198 ThinkServer RD640 User Guide and Hardware Maintenance Manual ...
Page 228: ...214 ThinkServer RD640 User Guide and Hardware Maintenance Manual ...
Page 229: ......
Page 230: ......