2
Output status LED
Status
Description
Action
Off
The server is off or the power supply is not
working properly.
If the power supply is not working properly,
replace the power supply. See “Hot-swap
power supply” on page 79.
Blinking green
(about one flash every
two seconds)
The power supply is in cold redundancy
active mode.
No action is needed.
Blinking green
(about two flashes
each second)
The power supply is in cold redundancy
sleep mode.
No action is needed.
Green
The server is on and the power supply is
working properly.
No action is needed.
3
Fault LED
Status
Description
Action
Off
The power supply is working properly.
No action is needed.
Amber
The power supply has failed.
Replace the power supply. See “Hot-swap
power supply” on page 79.
RAID card
This topic helps you locate the connectors on RAID cards. Your server supports the following RAID cards
(supported type varies by server model):
• Lenovo ThinkServer RAID 520i PCIe Adapter (hereinafter referred to as RAID 520i Adapter)
• Lenovo ThinkServer RAID 720i PCIe Adapter (hereinafter referred to as RAID 720i Adapter)
Note:
Depending on the configuration, the RAID card installed on your server might look slightly different
from illustrated.
27
Summary of Contents for ThinkServer TS460
Page 14: ...xii ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Page 52: ...38 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Page 68: ...54 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Page 138: ...124 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Page 144: ...130 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Page 148: ...134 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Page 160: ...146 ThinkServer TS460 User Guide and Hardware Maintenance Manual ...
Page 171: ......
Page 172: ......