background image

 

 

 

 

 
 
 

 

ThinkSystem RAID 940-8i 4GB Flash PCIe 

Gen4 12Gb Adapter Installation and User 

Guide 

 
 

 

 

 

Summary of Contents for ThinkSystem RAID 940-8i

Page 1: ...ThinkSystem RAID 940 8i 4GB Flash PCIe Gen4 12Gb Adapter Installation and User Guide ...

Page 2: ...enovo 2020 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 ...

Page 3: ...Host Interface 5 1 4 LED Management 6 1 5 Tri Mode Storage Interface Features 6 1 6 Adapter Characteristics 6 Chapter 2 Adapter Installation Instructions 8 Chapter 3 Marks Certifications Compliance and Safety Characteristics 10 3 1 Marks Certifications and Compliance 10 3 2 Safety Characteristics 11 ...

Page 4: ... following table summarizes key adapter features Table 1 Adapter Features Adapter 940 8i Ports 8 internal I O Processor SAS3908 Form Factor LP MD2 Storage Interface Connectors One SFF 8654 x8 Host Interface x8 PCIe 4 0 Storage Interface SAS SATA and PCIe NVMe Cache Memory 4 GB 2666 MT s DDR4 SDRAM Cache Protection Yes Super Capacitor CVPM05 module 1 1 RAID Features The following list includes prim...

Page 5: ...atest firmware and driver for the adapter 1 3 PCIe Host Interface The adapter s PCIe 4 0 host interface provides maximum transmission and reception rates of up to 128 GT s 16 Gb s per lane The tri mode controller uses a packet based communication protocol to communicate over the serial interconnect Other PCIe host interface features include the following Eight lane PCIe host interface PCIe Hot Plu...

Page 6: ... clock independent SSC SRIS support SAS features SAS data transfers at 12Gb s 6Gb s and 3Gb s DataBolt technology on all SAS phys to improve performance Serial point to point enterprise level storage interface Wide ports that contain multiple phys Narrow ports that contain a single phy SAS phy power management Data transfer by using SCSI information units T10 data protection management Support for...

Page 7: ... activity on the drives connected to the adapter J11 Global drive fault LED header 2 pin connector Connects to an LED that indicates whether a drive is in a fault condition J14 CacheVault power module interface 9 pin connector Connects the adapter to a CacheVault power module J17 C0 Storage interface connector One SFF 8654 8 port internal connector Connect the adapter by cable to the storage devic...

Page 8: ...d components with the screwdriver or the bracket b Remove the full profile bracket Do not damage the adapter c Place the adapter on top of the low profile bracket Position the bracket so that the screw holes in the tabs align with the openings in the board d Using a No 1 Phillips torque screwdriver that is ESD safe set to a maximum torque of 4 8 0 5 inch pounds Replace the two Phillips screws remo...

Page 9: ...tructions 8 Provide the required airflow for the installed adapter 9 Turn on the power to the system Reinstall the computer cover and reconnect the AC power cords Make sure that the power is turned on to the storage devices before or at the same time that the power is turned on to the host computer Turn on power to the host computer If the computer is powered on before these devices the devices mi...

Page 10: ...ifications Mark Symbol Description Australia and New Zealand RCM Meets the following standards AS NZS CISPR 32 CISPR 32 2015 Class B AS NZS CISPR 32 2015 Class B Canada EMC CANADA ICES OO3 CLASS B CANADA NMB 003 CLASSE B CAN ICES 3 B NMB 3 B Meets the following standards ICES 003 2016 Issue 6 2016 Class B CAN CSA CISPR 22 10 CISPR 22 2008 Europe CE Meets the following standards EN55022 EN55024 EN5...

Page 11: ...ing standards IEC 60950 1 2005 Second edition Am 1 2009 Am 2 2013 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 IEC 62368 1 2014 Second edition Japan VCCI Meets the following standards V 3 2015 04 Class B V 4 2012 04 VCCI CISPR 32 2016 USA Canada FCC Meets the following standards 47 CFR FCC Part 15 Subpart B Class B ANSI C63 4 2014 CISPR 32 2008 Country of Origin Made in XXXX XXXX indicates th...

Page 12: ...System RAID 940 8i 4GB Flash PCIe Gen4 12Gb Adapter Installation and User Guide 12 Trademarks LENOVO LENOVO logo and THINKSYSTEM are trademarks of Lenovo All other trademarks are the property of their respective owners 2020 Lenovo ...

Page 13: ......

Reviews: