Install the storage cage
Use this information to install the storage cage.
Before you install the storage cage, complete the following steps:
1. Read “Safety” on page iii and “Installation Guidelines” on page 21 to ensure that you work safely.
To install the storage cage, complete the following steps:
Watch the procedure
. A video of the installation process is available:
• Youtube: https://www.youtube.com/playlist?list=PLYV5R7hVcs-B4_LYuT9X1MRWBU6UzX9gO
• Youku: http://list.youku.com/albumlist/show/id_50481482
Figure 66. Storage cage installation
Step 1. Position the cage in the compute node front panel at an angle and rotate the cage into position on
the system board.
Step 2. Align the cage with the screw holes on the system board.
Step 3. Using a T10 Torx screwdriver, insert the four screws and secure the cage in the compute node.
After you install the storage cage, complete the following steps:
1. Install the 2.5” drive backplane (see “Install a 2.5-inch drive backplane” on page 29 ).
2. Install the bezel (see “Install the bezel” on page 36).
3. Install any removed storage drives, optional drive components, and drive bay fillers (see “Install a 2.5-
inch hot-swap drive” on page 27 ).
4. Install the compute node cover (see “Install the compute node cover” on page 43 ).
5. Install the compute node into the chassis (see “Install the compute node in the chassis” on page 25 ).
6. Power on the compute node.
System-board assembly replacement
Use the following information to remove and install the system-board assembly.
Remove and replace the system-board assembly
Notes:
• This procedure should be performed only by trained service technicians.
82
ThinkSystem SN550 Compute Node Maintenance Manual
Summary of Contents for ThinkSystem SN550
Page 1: ...ThinkSystem SN550 Compute Node Maintenance Manual Machine Type 7X16 ...
Page 8: ...vi ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 28: ...20 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 124: ...116 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 128: ...120 ThinkSystem SN550 Compute Node Maintenance Manual ...
Page 137: ......
Page 138: ...Part Number SP47A10572 Printed in China 1P P N SP47A10572 1PSP47A10572 ...