Note:
BMC, IMM, or XCC external LAN IP address, account name, and password are all
valid for this command.
Example that does use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SysInfoUUID <uuid_value>
Step 3. Restart the Lenovo XClarity Controller.
Step 4. Restart the solution.
Update the DMI/SMBIOS data
The Desktop Management Interface (DMI) must be updated when the system board is replaced. Use the
Lenovo XClarity Essentials OneCLI to update the DMI in the UEFI-based solution. Lenovo XClarity Essentials
OneCLI is an online tool that supports several operating systems; make sure that you download the version
for your operating system.
Notes:
You can use Lenovo XClarity Provisioning Manager to update the asset tag for the solution:
1. Start the solution and press F1 to display the Lenovo XClarity Provisioning Manager system setup
interface.
2. From the System Summary page, click
Update VPD
.
3. Update the asset tag information.
To download Lenovo XClarity Essentials OneCLI, go to the following site:
https://datacentersupport.lenovo.com/solutions/HT116433
Lenovo XClarity Essentials OneCLI sets the DMI in the Lenovo XClarity Controller. Select one of the following
methods to access the Lenovo XClarity Controller and set the DMI:
• Online from the target system, such as LAN or keyboard console style (KCS) access
• Remote access to the target system (LAN based)
Step 1. After you haveLenovo XClarity Essentials OneCLI in place, type the following commands to set the
DMI:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> [access_method]
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> [access_method]
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
Where:
<m/t_model>
The solution machine type and model number. Type
mtm xxxxyyy
, where
xxxx
is the machine
type and
yyy
is the solution model number.
<s/n>
The serial number on the solution. Type
sn zzzzzzz
, where
zzzzzzz
is the serial number.
<asset_method>
The solution asset tag number. Type
asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
, where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
is the asset tag number.
[access_method]
The access method that you select to use from the following methods:
• Online authenticated LAN access, type the command:
[−−imm xcc_user_id:xcc_password@xcc_internal_ip]
or
138
ThinkSystem SR860 Maintenance Manual
Summary of Contents for ThinkSystem SR860
Page 1: ...ThinkSystem SR860 Maintenance Manual Machine Type 7X69 7X70 ...
Page 8: ...vi ThinkSystem SR860 Maintenance Manual ...
Page 63: ...Figure 48 Server components Chapter 2 Server components 55 ...
Page 200: ...192 ThinkSystem SR860 Maintenance Manual ...
Page 210: ...202 ThinkSystem SR860 Maintenance Manual ...
Page 211: ......
Page 212: ...Part Number SP47A30805 Printed in China 1P P N SP47A30805 1PSP47A30805 ...