2. Make sure all the removed components are installed, and all the disconnected cables are reconnected.
To install the top cover, complete the following steps:
Watch the procedure
. A video of the process is available:
• Youtube:
https://www.youtube.com/watch?v=pIb0bIyfkDY&=PLYV5R7hVcs-Ak9fT8QAx8fLbEivizjRtp
• Youku:
http://v.youku.com/v_show/id_XMzMyODU3NTY2NA==.html?spm=a2hzp.8253876.0.0&f=51276390
Step 1. Press and hold on the blue tab of cover release latch; then, rotate the tip of the latch up.
Step 2. Place the top cover on top of the server with both sides aligned.
Step 3. Push the latch down until it clicks in place.
Figure 139. Top cover installation
After installing the top cover, complete the following steps:
1. Reconnect the power cords and any cables that you removed.
2. If the server is installed in a rack, reinstall the server into the rack.
3. Power on the server and any peripheral devices.
Replace components in the PCIe expansion tray
Use the following information to remove and install the components in the PCIe expansion tray.
PCIe expansion tray replacement
Use this procedure to install or remove the PCIe expansion tray.
Remove the PCIe expansion tray
Use this procedure to remove the PCIe expansion tray.
Before removing the PCIe expansion tray:
.
Hardware replacement procedures
149
Summary of Contents for ThinkSystem SR860
Page 1: ...ThinkSystem SR860 Maintenance Manual Machine Type 7X69 7X70 ...
Page 8: ...vi ThinkSystem SR860 Maintenance Manual ...
Page 63: ...Figure 48 Server components Chapter 2 Server components 55 ...
Page 200: ...192 ThinkSystem SR860 Maintenance Manual ...
Page 210: ...202 ThinkSystem SR860 Maintenance Manual ...
Page 211: ......
Page 212: ...Part Number SP47A30805 Printed in China 1P P N SP47A30805 1PSP47A30805 ...