4. Update the asset tag information.
• From Lenovo XClarity Essentials OneCLI
Lenovo XClarity Essentials OneCLI sets the asset tag in the Lenovo XClarity Controller. Select one of the
following methods to access the Lenovo XClarity Controller and set the asset tag:
– Operate from the target system, such as LAN or keyboard console style (KCS) access
– Remote access to the target system (TCP/IP based)
To update the asset tag from Lenovo XClarity Essentials OneCLI:
1. Download and install Lenovo XClarity Essentials OneCLI.
To download Lenovo XClarity Essentials OneCLI, go to the following site:
https://datacentersupport.lenovo.com/solutions/HT116433
2. Copy and unpack the OneCLI package, which also includes other required files, to the server. Make
sure that you unpack the OneCLI and the required files to the same directory.
3. After you have Lenovo XClarity Essentials OneCLI in place, type the following command to set the
DMI:
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
Where:
<asset_tag>
The server asset tag number. Type
asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
, where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
is the asset tag number.
[access_method]
The access method that you select to use from the following methods:
– Online authenticated LAN access, type the command:
[
--bmc
-username xcc_user_id
--bmc
-password xcc_password]
Where:
xcc_user_id
The BMC/IMM/XCC account name (1 of 12 accounts). The default value is USERID.
xcc_password
The BMC/IMM/XCC account password (1 of 12 accounts).
Example command is as follows:
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
--bmc
-username xcc_user_id
--bmc
-password xcc_password
– Online KCS access (unauthenticated and user restricted):
You do not need to specify a value for
access_method
when you use this access method.
Example command is as follows:
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
Note:
The KCS access method uses the IPMI/KCS interface, which requires that the IPMI
driver be installed.
– Remote LAN access, type the command:
[
−−bmc
xcc_user_id:xcc_password@xcc_external_ip]
Where:
270
ThinkSystem SR950 Setup Guide
Summary of Contents for ThinkSystem SR950
Page 1: ...ThinkSystem SR950 Setup Guide Machine Types 7X12 7X11 and 7X13 ...
Page 55: ...Figure 22 Server components Chapter 2 Server components 51 ...
Page 276: ...272 ThinkSystem SR950 Setup Guide ...
Page 282: ...278 ThinkSystem SR950 Setup Guide ...
Page 286: ...282 ThinkSystem SR950 Setup Guide ...
Page 389: ......
Page 390: ......