Figure 63. RAID card connectors (type 2)
Table 230. RAID card connectors (type 2)
Callout
Callout
1
RAID flash power module (J14) connector
3
RAID connector for drive backplane 1 or 4 (SAS only)
2
RAID connector for drive backplane 2 or 5 (SAS only)
4
PCI connector to storage interposer
Drive backplane connectors
The following illustration shows the internal connectors on the drive backplanes.
Note:
Some cable connectors have locks or latches that must be disengaged to disconnect the cable.
There are two types of drive backplane used in the server: one that controls only SAS drives and one that
controls both SAS and NVMe drives. Cable routing for drive components is different for SAS and SAS/NVMe
drives:
• SAS drive backplane connectors
• SAS/NVMe drive backplane connectors
For information about drive backplane cable routing, see “Cable routing for drives” on page 40.
SAS drive backplane connectors
Figure 64. SAS drive backplane connectors
Table 231. SAS drive backplane connectors
Callout
Callout
1
Drive connector for SAS drives 0, 4, 8, 12, 16, and 20
4
Drive connector for SAS drives 3, 7, 11, 15, 19, and 23
2
Drive connector for SAS drives 2, 6, 10, 14, 18, and 22
5
SAS signal from RAID card
3
Drive connector for SAS drives 1, 5, 9, 13, 17, and 21
6
Backplane power from interposer
Appendix B. Component reference
291
Summary of Contents for ThinkSystem SR950
Page 1: ...ThinkSystem SR950 Setup Guide Machine Types 7X12 7X11 and 7X13 ...
Page 55: ...Figure 22 Server components Chapter 2 Server components 51 ...
Page 276: ...272 ThinkSystem SR950 Setup Guide ...
Page 282: ...278 ThinkSystem SR950 Setup Guide ...
Page 286: ...282 ThinkSystem SR950 Setup Guide ...
Page 389: ......
Page 390: ......