The BMC/IMM/XCC account password (1 of 12 accounts).
Example commands are as follows:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
--bmc
-username xcc_user_id
--bmc
-password xcc_password
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
--bmc
-username xcc_user_id
--bmc
-password xcc_password
– Online KCS access (unauthenticated and user restricted):
You do not need to specify a value for
access_method
when you use this access method.
Example commands are as follows:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
Note:
The KCS access method uses the IPMI/KCS interface, which requires that the IPMI
driver be installed.
– Remote LAN access, type the command:
[
−−bmc
xcc_user_id:xcc_password@xcc_external_ip]
Where:
xcc_external_ip
The BMC/IMM/XCC IP address. There is no default value. This parameter is required.
xcc_user_id
The BMC/IMM/XCC account (1 of 12 accounts). The default value is USERID.
xcc_password
The BMC/IMM/XCC account password (1 of 12 accounts).
Note:
BMC, IMM, or XCC internal LAN/USB IP address, account name, and password are all
valid for this command.
Example commands are as follows:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
−−bmc
xcc_user_id:xcc_password@xcc_external_ip
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
−−bmc
xcc_user_id:xcc_password@xcc_external_ip
4. Reset the Lenovo XClarity Controller to the factory defaults. See “Resetting the BMC to Factory
Default” section in the XCC documentation compatible with your server at
sysmgt.lenovofiles.com/help/topic/lxcc_frontend/lxcc_overview.html
Enable TPM/TCM
The server supports Trusted Platform Module (TPM), Version 1.2 or Version 2.0
Note:
For customers in Chinese Mainland, TPM is not supported. However, customers in Chinese Mainland
can install a Trusted Cryptographic Module (TCM) adapter (sometimes called a daughter card).
When a system board is replaced, you must make sure that the TPM/TCM policy is set correctly.
CAUTION:
Take special care when setting the TPM/TCM policy. If it is not set correctly, the system board can
become unusable.
Set the TPM policy
By default, a replacement system board is shipped with the TPM policy set to
undefined
. You must modify
this setting to match the setting that was in place for the system board that is being replaced.
338
ThinkSystem SR950 Setup Guide
Summary of Contents for ThinkSystem SR950
Page 1: ...ThinkSystem SR950 Setup Guide Machine Types 7X12 7X11 and 7X13 ...
Page 55: ...Figure 22 Server components Chapter 2 Server components 51 ...
Page 276: ...272 ThinkSystem SR950 Setup Guide ...
Page 282: ...278 ThinkSystem SR950 Setup Guide ...
Page 286: ...282 ThinkSystem SR950 Setup Guide ...
Page 389: ......
Page 390: ......