CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
S017
CAUTION:
Hazardous moving fan blades nearby.
Remove the air baffle
Use this information to remove the air baffle.
Before removing the air baffle:
1. If the server is installed in a rack, extend the server from the rack.
2. Remove the server cover. See “Remove the server cover” on page 68.
3. If there is a RAID super capacitor module installed on the air baffle, disconnect the RAID super capacitor
module cable first.
To remove the air baffle, complete the following step:
Watch the procedure
. A video of the removal process is available:
• Youtube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-Acsjj4tU79GzKnWG316BYn
• Youku:
http://list.youku.com/albumlist/show/id_50483452
Step 1. Lift up the front end of the air baffle until the rear end of the air baffle is disengaged from the
chassis. Then, remove the air baffle out of the chassis.