Turning off the server
Use this information to turn off the server.
When you turn off the server and leave it connected to ac power, the server can respond to requests to
the service processor, such as a remote request to turn on the server. While the server remains connected
to ac power, one or more fans might continue to run. To remove all power from the server, you must
disconnect it from the power source.
Some operating systems require an orderly shutdown before you turn off the server. See your
operating-system documentation for information about shutting down the operating system.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
1
2
The server can be turned off in any of the following ways:
• You can turn off the server from the operating system, if your operating system supports this feature. After
an orderly shutdown of the operating system, the server will turn off automatically.
• You can press the power-control button to start an orderly shutdown of the operating system and turn off
the server, if your operating system supports this feature.
• If the operating system stops functioning, you can press and hold the power-control button for more
than 4 seconds to turn off the server.
• The server can be turned off by Wake on LAN feature with the following limitation:
Note:
When you install any PCI adapter, the power cords must be disconnected from the power source
before you remove the PCI Express assembly and the PCI-X assembly. Otherwise, the active power
management event signal will be disabled by the system-board logic, and the Wake on LAN feature
might not work. However, after the server is powered-on locally, the active power management event
signal will be enabled by the system-board logic.
• The integrated management module II (IMM2) can turn off the server as an automatic response to a
critical system failure.
• The server turns off when the left-side cover is opened.
24
System x3300 M4 Installation and Service Guide
Summary of Contents for x3300 M4 7382
Page 1: ...System x3300 M4 Installation and Service Guide Machine Type 7382 ...
Page 6: ...iv System x3300 M4 Installation and Service Guide ...
Page 14: ...xii System x3300 M4 Installation and Service Guide ...
Page 166: ...152 System x3300 M4 Installation and Service Guide ...
Page 176: ...162 System x3300 M4 Installation and Service Guide ...
Page 704: ...690 System x3300 M4 Installation and Service Guide ...
Page 888: ...874 System x3300 M4 Installation and Service Guide ...
Page 896: ...Taiwan BSMI RoHS declaration 882 System x3300 M4 Installation and Service Guide ...
Page 906: ...892 System x3300 M4 Installation and Service Guide ...
Page 907: ......
Page 908: ......