CAUTION:
The power control button on the device and the power switch on the power supply do not turn off
the electrical current supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
1
2
The server can be turned off in any of the following ways:
• You can turn off the server from the operating system, if your operating system supports this feature. After
an orderly shutdown of the operating system, the server will turn off automatically.
• You can press the power-control button to start an orderly shutdown of the operating system and turn off
the server, if your operating system supports this feature.
• If the operating system stops functioning, you can press and hold the power-control button for more
than 4 seconds to turn off the server.
• The server can be turned off by Wake on LAN feature with the following limitation:
Note:
When you install any PCI adapter, the power cords must be disconnected from the power source
before you remove the PCI Express riser-card assembly and the PCI-X riser-card assembly. Otherwise,
the Wake on LAN feature might not work.
• The Integrated Management Module (IMM) can turn off the server as an automatic response to a critical
system failure.
22
System x3550 M4 Installation and Service Guide
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......