CIM Information
Prefix:
PLAT
ID:
0508
User Response
1. Replace the power supply with higher rated power.
2. Reduce the total power consumption by removing newly added or unused option like drives or
adapters.
•
80070101-0c01ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (Ambient Status)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701010c01ffff or 0x800701010c01ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix:
PLAT
ID:
0520
User Response
1. Check the microprocessor installed is Intel E5-2690.
2. Reduce the ambient temperature under 27 Celsius degree.
•
8007010f-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (GPT Status)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 8007010f2201ffff or 0x8007010f2201ffff
Severity
Warning
404
System x3550 M4 Installation and Service Guide
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......