800b010a-1e81ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Fan
Zone 1)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix:
PLAT
ID:
0802
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4.
Reseat the fans.
5. Replace the fans. (n = fan number)
•
800b010a-1e82ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Fan
Zone 2)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e82ffff or 0x800b010a1e82ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
Appendix A. Integrated management module II (IMM2) error messages
421
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......