8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10.
If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server
to the power source and restart the server.
9. (Trained Service technician only) Replace the affected microprocessor.
•
806f010c-200effff : Uncorrectable error detected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 14)
This message is for the use case when an implementation has detected a Memory uncorrectable error.
May also be shown as 806f010c200effff or 0x806f010c200effff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix:
PLAT
ID:
0138
User Response
1. Refer to TIP H212293 for minimum code level.
2. Check the IBM support website for an applicable retain tip or firmware update that applies
to this memory error.
3. Swap the affected DIMMs (as indicated by the error LEDs on the system board or the event
logs) to a different memory channel or microprocessor.
4. If the problem follows the DIMM, replace the failing DIMM.
5. (Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM
connector. If the connector contains any foreign material or is damaged, replace the system
board.
6. (Trained technician only) Remove the affected microprocessor and check the microprocessor
socket pins for any damaged pins. If a damage is found, replace the system board.
7. (Trained technician only) Replace the affected microprocessor.
8. Manually re-enable all affected DIMMs if the server firmware version is older than UEFI v1.10.
If the server firmware version is UEFI v1.10 or newer, disconnect and reconnect the server
to the power source and restart the server.
9. (Trained Service technician only) Replace the affected microprocessor.
Appendix A. Integrated management module II (IMM2) error messages
457
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......